EasyManua.ls Logo

Acer V193

Acer V193
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 7 -
3.2. Operational Specification
3.2.1 Power supply
Item
Condition
Spec
N.A
Remark
Input Voltage range
Universal input full range
90~264VAC /47~63Hz
Input Current range
90 ~ 264VAC
< 0.7 Arms
Power Consumption
Normal “On” operation
< 31 W
LED: Blue
DPMS
DPMS “Sleep” state
< 1 W
LED: Amber
DPMS
DPMS “Off” state
< 0.5 W
LED: OFF
Inrush Current
110 VAC
220 VAC
< 30 A (peak)
< 60 A (peak)
Cold-start
Earth Leakage Current
264 VAC/50Hz
< 3.5 mA
Hi-Pot
1. 1500VAC, 1 sec
2. Ground test: 30A,
1sec
Without damage
< 0.1 ohm
(on-line test)
(in-lab test)
Power Line Transient
IEC1000-4-4
1KV
IEC1000-4-5 (Surge)
Common: 2KV,
Differential: 1KV

Other manuals for Acer V193