SGM1400-B Series Smart Meter
Single Phase User Manual - SMETS2
Y20974-TUM
Revision B
www.Aclara.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Aclara SGM1411-B and is the answer not in the manual?

Aclara SGM1411-B Specifications

General IconGeneral
BrandAclara
ModelSGM1411-B
CategoryMeasuring Instruments
LanguageEnglish

Summary

Chapter 2: Product Description

Chapter 3: Physical Components

METER SECURITY AND DETECTION

Detection and recording of tamper incidents and magnetic detection.

Chapter 4: Communications

Chapter 5: Metrology Functionality

INSTANTANEOUS MEASUREMENTS

Available electrical parameters measured at short intervals.

POWER QUALITY MEASUREMENTS

Support for power quality events like voltage, frequency, and current anomalies.

VOLTAGE QUALITY MEASUREMENTS

Support for average RMS and extreme voltage measurements.

SAG/SWELL AND FREQUENCY EVENTS

Configuration of voltage sag/swell and frequency deviation thresholds.

OVER CURRENT AND POWER FACTOR MONITORING

Monitoring of over current and power factor thresholds for events.

VOLTAGE THRESHOLD ANALYSIS

Analysis of over, under, and extreme voltage thresholds.

VOLTAGE SAG/SWELL AND OUTAGE REPORTING

Detection of voltage sag/swell and recording of supply outages.

PROFILES AND DATA STORAGE

Non-volatile recording of load, instrumentation data, and general data storage.

LOAD AND VOLTAGE PROFILES

Configuration for load profiles and voltage profile logging.

TIME-OF-USE (TOU) AND BLOCK TARIFFS

Support for TOU registers, tariff structures, and block tariffs.

Chapter 6: Advanced Features

SUPPLY DISCONNECT AND RECONNECT

Functionality for disconnecting and reconnecting the supply via a contactor.

LOAD LIMITING AND FREQUENCY CONTROL

Disconnection based on power thresholds and frequency deviations.

SAG/SWELL, OVER CURRENT, AND POWER FACTOR EVENTS

Monitoring for voltage sag/swell, over current, and power factor deviations.

EVENT LOGGING AND PREPAYMENT SOLUTION

Continuous monitoring, logging, and overview of prepayment functionality.

CHARGE OBJECT TYPES AND PAYMENT MODES

Types of charges and the two operational payment modes: Credit and Prepayment.

PREPAYMENT MODE OPERATIONS

How credits and charges are utilized in Prepayment Mode.

NON-DISABLEMENT CALENDAR AND INDICATORS

Calendar for non-disablement periods and display indication.

UTRN (TOKEN) TOP-UPS AND FORMATS

Applying credit top-ups using UTRNs and details on token formats.

UTRN TOKEN DETAILS AND CACHE

Structure, MAC, manual entry, and counter cache for UTRN tokens.

METER BALANCE, CREDIT THRESHOLDS, AND DEBT TO CLEAR

Limits on meter balance, credit, and amount required to clear debt.

DEBT RECOVERY ORDER AND EVENTS

Priority for debt recovery and list of prepayment events/alerts.

PREPAYMENT MENU DISPLAY AND ITEMS

Accessing prepayment quantities via menu and mandatory menu items.

Chapter 7: Installation

CONNECTING TO CSP COMMUNICATIONS HUB

Procedure for pairing the meter with the CSP communication hub.

Chapter 8: Tests Procedures and Maintenance

FIELD ACCURACY AND WATT-HOUR TESTS

Procedures for testing meter accuracy in the field and conducting watt-hour tests.

Chapter 9: Specifications