Servicing System Transformers
NOTES:
High Voltage! Do NOT touch while system is operating or
plugged into a power outlet. Risk of severe electrical shock.
Do NOT perform maintenance on this item. Call for service if
ozone generator shows any sign of damage.
Do not try to repair a transformer. This is a replacement
component only.
The system transformers increase the supply voltage to 4200 V at less than 0.5 amp
draw. The increase supplies proper voltage to the corona discharge generator for
ozone production. There are several sources for transformer failure:
Over draw by ozone generator as a result of failure or arcing.
Power surges.
The loss of proper energy input into the corona discharge generator can lead to coil
and generator failure, potentially damaging both permanently.
Replace only with Aclarus high quality transformers. Aclarus transformers come with
replacement instructions.
NOTE: If fuses blow again after replacement, call an Aclarus service technician to
report the situation.