15. R-Prism Reset Error
Check if the position of the Prism mounting magnetic steel falls off or is damaged.
Check if there are other interference items in the Prism operating range.
Check if the Prism Hall elements is damaged.
Check if the Prism Hall elements is in poor contact with the lead of the PCB board or disconnected.
Check if the Prism motor is damaged.
Check if there is any damage to the circuit of the Prism motor drive board.
16. Focus Reset Error
Check if the position of the focus mounting magnetic steel falls off or is damaged.
Check if there are other interference items in the focus operating range.
Check if the focus Hall elements is damaged.
Check if the focus Hall elements is in poor contact with the lead of the PCB board or disconnected.
Check if the focus motor is damaged.
Check if there is any damage to the circuit of the focus motor drive board.
17. Zoom Reset Error
Check if the position of the zoom mounting magnetic steel falls off or is damaged.
Check if there are other interference items in the zoom operating range.
Check if the zoom Hall elements is damaged.
Check if the zoom Hall elements is in poor contact with the lead of the PCB board or disconnected.
Check if the zoom motor is damaged.
Check if there is any damage to the circuit of the zoom motor drive board.
18. Led Temp. Error
Check if the temperature detecting board is normal.
Check if the components of the temperature detecting board are damaged.
Check if the lead of the temperature detecting board is installed in place or disconnected.
19. Led Temp. Too High
Check if the fan is working properly.
Check if the fan speed is normal.
Check if the ambient temperature is abnormal.
20. BaseFan1/2 Start Err
Check if the fan is not running.
Check if the fan leads are installed in place or disconnected.
34C