- 93 -
Tilt Encode Disable
Network Error
Zoom Error
LED Timeout Use
LED Too Hot Off
LED Temp. 1/2/3 Error
Check whether the network module is installed.
Check whether the network module is damaged.
When the fixture temperature reaches 86ā„ƒ, it will automatically turn
off to protect the fixture.
Check whether the position of the zoom where the magnet is
installed falls off or is damaged.
Check whether there are obstacles in the zoom operating range.
Check whether the Hall element on the zoom is damaged.
Check whether the lead connecting the Hall element on the zoom and
the PCB board is in poor contact or disconnected.
Check whether the motor on the zoom is damaged.
Check whether the related circuit of the motor drive board on the
zoom is damage.
Check whether the encoder on the tilt is damaged.
Check whether the temperature detecting board is normal.
Check whether the components of the temperature detecting board
are damaged.
Check whether the lead on the temperature detecting board is
installed in place or disconnected.