Do you have a question about the Acom 2100 and is the answer not in the manual?
The transformer weighs 30kg; handle with two persons and support securely.
Position amplifier flat, remove cover (9 M3x6 screws), orient compartment forward, and unplug connectors.
Remove transformer from packaging, keep shipping materials, use provided M6x12 screws.
Align transformer, use lock/flat washers, loosely screw in, then tighten all 4 screws.
Requires an assistant to support the amplifier as captive nuts are accessed.
Plug in the filament supply connector and HV fast-on connectors to the HV Rectifier board.
Thread 8 primary leads of the HV-transformer through chassis openings, using rubber grommets.
Connect HV-transformer primary wires to voltage selector terminals based on mains voltage table.
Connect remaining connectors, replace cover, reinstall screws, and check fuses for 100-120VAC.