MOB USER MANUAL
21 Y1-03-0283 Rev. C
8.5 Specifications
AIS transmission
Transmit Power (EIRP)...................................................................................... 1Watt
Frequency .................................................................... 161.975/162.025MHz ±500Hz
Baud rate ................................................................................................... 9600baud
Synchronisation ...................................................................................................UTC
Messages ........................................... Message 1 (Position), Message 14 (MOB status)
Repetition interval......................................................................... 8 messages/minute
...................................................................... Message 14 sent twice every 4 minutes
DSC Transmission
1
Transmit Power (EIRP).................................................................................. 0.5Watt
Frequency ............................................................................................. 156.525MHz
Messages ......................................................................... Individual Distress Relay*
............................................................................................ All Ships Distress Alert*
1
Message repetition ................................................. Once every 5 minutes (Relay only)
Baud rate ................................................................................................... 1200baud
*Single call made on press of the activation button, in regions where it is allowed.
Environmental
Temperature range (operational) .......................................................... -20°C - +55°C
Temperature range (storage) ............................................................... -30°C -+70°C
Damp Heat (humidity) .......................................................................... 40°C at 93%
Drop (hard surface) ............................................................................... 1m : 6 sides]
Designed to meet Drop (water) .............................................................. 20m : 3sides
Water immersion ......................................................................... 2 bar : >60minutes
Thermal Shock ...................................................... 45° into 100mm of water : >1hour
Physical
Weight ........................................................................................................ 92grams
Dimensions........................................................................... 134mm x 38mm x27mm
.................................................................................................... 59mm over bracket
Battery
Operational life .......................................................................................... 24+ hours
Battery Life..................................................................................................... 7 years
8.6 Country of Intended Use
Austria
Germany
Netherlands
Belgium
Greece
Poland
Bulgaria
Hungary
Portugal
Cyprus
Ireland
Romania
Czech Republic
Italy
Slovakia
Denmark
Latvia
Slovenia
Estonia
Lithuania
Spain
Finland
Luxembourg
Sweden
France
Malta
United Kingdom
The Country of Intended Use Table is an EU requirement only
1
DSC functionality is subject to the regulations of the country.

Related product manuals