EasyManua.ls Logo

ACR Electronics AIS Link MOB - In Case of Emergency; Manual Activation

ACR Electronics AIS Link MOB
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MOB USER MANUAL
3 Y1-03-0283 Rev. C
IN CASE OF EMERGENCY
Use only in situations of grave
or imminent danger.
The MOB is intended to be fitted to a life jacket. If the MOB is
correctly fitted to the life jacket, then it will automatically activate
when the life jacket inflates. This guide shows how to manually
activate the MOB.
Press either of the grey Arming Retainers down (1)
Slide the grey Activation Slide (2) sideways towards the
depressed Arming Retainer and remove. This will release the
antenna and activate the MOB.
If the strobe light does not start flashing, manually switch the
MOB on by pressing the ON Key (3)
Always turn the MOB off immediately after you have been rescued
to avoid interference with other users. To deactivate, press the
TEST/OFF button until the LED flashes red twice, then release.
2
1
1
Warning: Do not place
eyes near Activation Slide.

Related product manuals