EasyManua.ls Logo

Acson A5WMY User Manual

Acson A5WMY
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERVICE
GUIDE BOOK

Questions and Answers:

Acson A5WMY Specifications

General IconGeneral
BrandAcson
ModelA5WMY
CategoryAir Conditioner
LanguageEnglish

Summary

1.0 Model Name

1.1 Product Name Description

Details product name descriptions for various ACSON models.

1.2 Nomenclature

Explains the product nomenclature for indoor units.

Outdoor Unit Nomenclature

2.0 Conversion Table

2.1 Conversion Table

Detailed conversion table for capacity, pressure, flow rate, temperature, velocity, volume, and area.

3.0 Product Mainboard vs. Handset Matrix

3.1 Product Mainboard vs. Handset Matrix

Table detailing mainboard compatibility with various handset models.

4.0 Controller Development History

4.1 Controller Development History

Chronological overview of controller development with model and year details.

5.0 Handset Operating Guide

5.1 G6

Operating instructions for the G6 remote control handset.

5.2 G8

Operating instructions for the G8 remote control handset.

5.3 G12

Operating instructions for the G12 remote control handset.

5.3 G18

Operating instructions for the G18 remote control handset.

5.4 GS02

Operating instructions for the GS02 remote control handset.

5.5 APJ2

Operating instructions for the APJ2 remote control handset.

5.6 SLM3

Operating instructions for the SLM3 remote control handset.

5.7 Sequential Controller

Operating guide for the sequential controller.

5.8 Netware 3

Operating guide for the Netware 3 handset.

6.0 Controller Configuration

6.1 Auto Random Restart

Configuration for auto random restart feature on mainboards.

6.2 Hot Keep Selection

Configuration options for the hot keep function.

6.3 Auxiliary Heater Conversion

Components needed to convert U1.5 heatpump to auxiliary heater.

6.4 Multi Split Conversion

Instructions for converting units to multi split mode.

6.5 Sequential Controller

Configuration options for sequential controllers using dip switches.

6.9 WMF U1.4 to L2EF Conversion

Procedure for converting WMF U1.4 units to L2EF.

6.6 Chilled Water Fan Coil Unit (W1V3)

Configuration for W1V3 chilled water fan coil units using valve jumpers.

6.7 Chilled Water Fan Coil Unit (W2.0)

Configuration for W2.0 chilled water fan coil units using jumpers.

6.8 U1.5 L208A Conversion

Conversion process from U1.5 to L208A for single split indoor units.

9. Conversion from Old Sequential Board to New Sequential Board

7.0 Service Diagnosis

7.1 Self Diagnosis Table

Table for self-diagnosis using LED indicators on Wall Mounted F Series.

7.2 General Check

General troubleshooting steps for common AC unit problems.

7.3 General Troubleshooting Guide

Troubleshooting guide based on pressure readings and diagnostic flowcharts.

Inverter X Outdoor Unit Error Diagnosis

Chilled Water Fan Coil Unit Self Diagnosis (W1V3)

Ceiling Cassette Water Source Split Unit Self Diagnosis

Inverter Y Model Indoor Series Error Diagnosis

Wall Mounted K-Series Inverter Y Error Diagnosis

Multi Digital Scroll Indoor Units Error Diagnosis

Error Diagnosis by Wired Controller (MC301)

Troubleshooting errors using the MC301 wired controller.

Multi Digital Scroll Outdoor Units Error Diagnosis

Mini Chiller Troubleshooting Guide

Rooftop Troubleshooting Guide

Appendix: Resistance-Temperature Characteristics

Related product manuals