EasyManua.ls Logo

ActronAir CAY700T User Manual

ActronAir CAY700T
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
IMPORTANT NOTE:
Please read this manual carefully before installing or operating your air conditioning unit.
That’s better. That’s Actron.
Split Tri-Capacity
Installation and Commissioning Guide
INDOOR UNITS
LOW PROFILE
ELY500T
ELY620T
ELY700T
INDOOR UNITS
STANDARD PROFILE
EVY500T
EVY620T
EVY700T
OUTDOOR UNITS
CAY500T
CAY620T
CAY700T

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ActronAir CAY700T and is the answer not in the manual?

ActronAir CAY700T Specifications

General IconGeneral
BrandActronAir
ModelCAY700T
CategoryAir Handlers
LanguageEnglish

Summary

Introduction

Product Inspections

Check the air conditioning unit and items against the invoice for any damage and verify model and serial numbers.

Safety Precautions

Installation Information

Unit Mounting and Location

Condensate and Safety Tray Drainage Instructions

Unit Preparation

Outdoor Unit - Interconnecting Pipes Installation

Procedure for removing access panels and installing interconnecting pipes on the outdoor unit.

Compressor Shipping Blocks Removal

Steps to safely remove compressor shipping blocks and mount compressors securely.

Electrical Mains

Procedure for connecting electrical mains and securing cables within the unit.

Piping

Piping Connection

Notes on R-410A refrigerant, cleanliness, brazing, evacuation, and pipe length limitations.

Pipe Installation

Precaution for brazing joints with nitrogen and details on refrigerant piping sizes.

Electrical

Split Unit Electrical Connection

Diagrams and table for power circuit breaker size and cable size requirements.

External Input Operation

EC Indoor Fan Commissioning

Procedure for commissioning EC indoor fans using external input.

Compressor Configuration

Procedure for configuring compressor operation via external inputs.

Internal Sensor Operation

Unit ON/OFF Configuration

Options for configuring unit ON/OFF: Manual, Time Scheduler, or External.

Indoor Fan Configuration

Procedure for setting indoor fan speed via control interface.

Setting Economy Cycle Operation

Room Air Temperature Setup in Control Interface

Enable / Disable Air Filter Alarm

External Input Wiring Diagrams

24VAC Relay Output Compressors and Indoor Fans

Wiring diagram for 24VAC relay output to compressors and indoor fans.

0-10 Analogue Output Compressor and 24VAC Relay Output Indoor Fans

Wiring diagram for 0-10V analogue output to compressors and 24VAC to indoor fans.

24VAC Relay Output Compressor and 0-10 Analogue Output Indoor Fans

Wiring diagram for 24VAC relay output to compressors and 0-10V to indoor fans.

Wiring Diagram 0-10 Analogue Output Compressors and Indoor Fans

Wiring diagram for 0-10V analogue output to compressors and 24VAC relay to indoor fans.

Refrigerant Charging

Charging Method 1: Subcooling and Superheat

Procedure for charging refrigerant using subcooling and superheat measurements.

Charging Method 2: Cooling Charging Curve

Procedure for charging refrigerant using a cooling charging curve.

Thermal Expansion Valve (TXV) Adjustment

Instructions for adjusting the thermal expansion valve (TXV) for superheat control.

Fault Display Codes

Maintenance

Maintenance Frequency Checklist

Start-Up and Commissioning Report