PKY470T-6Q2
PKY540T-6Q2
PKY620T-6Q2
PKY700T-6Q2
INSTALLATION & COMMISSIONING GUIDE
Please Read This Guide
Congratulations on your purchase of an
ActronAir air conditioning system. This unit
has been designed and manufactured with the
highest quality standard in mind.
Please read this guide thoroughly and keep it
near the unit for future reference.
REVISION PKY470-700 INSTALL GUIDE 0525-032:
1. 140225 - PCR ---- - Version 1.01 - revision to Commercial Controls - WG/TN.
2. 140702 - Ver. 1.02 - 2nd Draft - Reected corrections to Electricals - TN.
3. 141010- VER. 1.0 SIGNED OFF -KM.
4. 141105 - VER.2.0 - pcr ____ REVISIONS TO FAN SUPPLY WITHOUT NEUTRAL AND START UP & COMMISSIONING REPORT UPDATED 0515-8803 - BM/SS/TN.
5. 150720 - PCR2462 - REVISED 3RD PARTY CONTROL TO COMPRESSORS & INDOOR FANS MODES OF OPERATION - TN.
6. 160120 - PCR2671 - software revision re: CL01 - BR/DB - TN. + 161027 PCR2781 - SPIDER MOUNT WITH VERTICAL STRUTS - EK/TN.
7. 170308 - PCR2838 - REVISED CONDENSATE DRAIN DETAILS - MW/WW - TN.
8. 170205 - PCR2930 - Add details on installation of outdoor unit. Installation preparation section (page 3) - WG/DR
PKY470T - PKY700T TRI-CAPACITY
WITH COMMERCIAL CONTROL

Questions and Answers

  • R
    Rachel ChandlerAug 12, 2025
    What to do if ActronAir Air Handlers show a Compressor HP Fault?
    • R
      Richard RandallAug 13, 2025
      If your ActronAir Air Handlers unit displays a Compressor HP Fault, begin by checking the outdoor fan operation and ensure the coils are clean. Verify that there isn't an excess refrigerant charge or any non-condensibles present, using a pressure-temperature chart for reference. Also, check the HP switch for continuity; a fault condition means there is no continuity.
  • K
    Kelly WilliamsAug 16, 2025
    What to do if ActronAir PKY470T-6Q2 Air Handlers show a Compressor LP Fault?
    • A
      Alexis SmithAug 16, 2025
      If your ActronAir Air Handlers unit displays a Compressor LP Fault, you should check for insufficient refrigerant charge and the presence of non-condensibles, using a pressure-temperature chart for reference. Also, check the LP switch for continuity; a fault condition means there is no continuity.
  • J
    Jennifer RobinsonAug 20, 2025
    What to do if ActronAir PKY470T-6Q2 show a Filter Alarm?
    • D
      Dr. Richard SmithAug 20, 2025
      If your ActronAir Air Handlers unit displays a Filter Alarm, inspect the filter for dirt. If it's dirty, clean it or replace it as needed.
  • S
    Susan LeeAug 25, 2025
    What to do if ActronAir PKY470T-6Q2 Air Handlers show a Room Air Temp Sensor Fault?
    • J
      Jennifer MitchellAug 25, 2025
      If your ActronAir Air Handlers unit displays a Room Air Temp Sensor Fault, check the wiring and the resistance through the sensor probe.
  • T
    tonymaynardAug 28, 2025
    What to do if ActronAir PKY470T-6Q2 show an Outdoor Air Temp Sensor Fault?
    • D
      Daniel HessAug 28, 2025
      If your ActronAir Air Handlers unit displays an Outdoor Air Temp Sensor Fault, check the wiring and the resistance through the sensor probe.
  • P
    Paul BlackwellAug 31, 2025
    What to do if ActronAir PKY470T-6Q2 Air Handlers show an Indoor Coil Sensor Fault?
    • J
      Joseph PhillipsAug 31, 2025
      If your ActronAir Air Handlers unit displays an Indoor Coil Sensor Fault, check the wiring and the resistance through the sensor probe.
  • A
    Amy BennettSep 4, 2025
    What to do if ActronAir PKY470T-6Q2 Air Handlers show an Outdoor Coil Temp1 Fault?
    • L
      Laura MartinezSep 4, 2025
      If your ActronAir Air Handlers unit displays an Outdoor Coil Temp1 Fault, check the wiring and the resistance through the sensor probe.
  • E
    Eric MorrisSep 8, 2025
    What to do if ActronAir Air Handlers show an Outdoor Coil Temp 2 Fault?
    • M
      Megan ThomasSep 8, 2025
      If your ActronAir Air Handlers unit displays an Outdoor Coil Temp 2 Fault, check the wiring and the resistance through the sensor probe.

ActronAir PKY470T-6Q2 Specifications

General IconGeneral
ModelPKY470T-6Q2
CategoryAir Handlers
RefrigerantR410A
Cooling Capacity47 kW
Power Supply415V 3Ph 50Hz