Installation instruction
Control Panel for Fire Ventilation
SVM EI 24V-5A / SVM EI 24V-8A
Fire ventilation
Comfort ventilation
24VDC max. 5A/8A
1 re ventilation group, 1 comfort group
Connection for manual control points, wind- and rain sensor, comfort switches, smoke detectors and
Fireman’s Priority Switch.
Possibility for bus connection of 35 control panels
#211534
Question and Answer IconNeed help?

Do you have a question about the Actulux SVM EI 24V-5A and is the answer not in the manual?

Summary

General Description and Safety

General Description

Provides an overview of the control panel's capabilities for fire and comfort ventilation.

Safety Rules and Precautions

Details critical safety guidelines for installation, operation, and handling, including explosion danger.

Connections and Monitoring

Motor Output and Line Monitoring

Explains connecting actuators and configuring line monitoring for motor outputs.

Current Limiter (LIP) Function

Describes the function and settings of the Current Limiter type LIP for actuators.

Operation and Control

Manual Control Points

Details the operation and connection of manual control points and their indicators.

Detector Inputs and Auto Reset

Covers connection of smoke/heat detectors, fire switches, and auto reset functionality.

Comfort Ventilation Settings

Explains how to connect and configure comfort ventilation features using potentiometers.

Wiring Diagram

SVM EI 24 V Connection Diagram

Illustrates the complete wiring connections for the SVM EI 24V-5A/8A control panel.

Indicators and Settings

LEDs on Main Board and Front Panel

Describes the function of various LEDs on the control panel for status indication.

Complete Jumper Settings

Details the factory-mounted and dismounted settings for DIP switches and jumpers.

System Integration

Bus Connection

Explains how to connect multiple control panels into a single system via bus communication.

Weather and External Alarm Connections

Covers connecting weather sensors and interfacing with fire alarm panels or other systems.

Special Functions and Cabling

Special Functions

Details specific functions like sprinkler activation, weekly open/close, and heat detector input.

Firemans Priority Switch

Describes the override switch for manual control by fire personnel.

Cable Specifications

Provides guidance on selecting correct cable types and sizes for fire ventilation systems.

Advanced Operating Modes

Lock-Out Mode SLAVE

Explains the Lock-Out mode for slave units, typically mandatory in the UK.

Lock-Out Mode MASTER

Explains the Lock-Out mode for the master unit, typically mandatory in the UK.

Parts and Accessories

Service and Maintenance

Service;Maintenance Record

A log for recording service dates, company, engineer, and maintenance notes.

Technical Specifications

Actulux SVM EI 24V-5A Specifications

General IconGeneral
BrandActulux
ModelSVM EI 24V-5A
CategoryControl Panel
LanguageEnglish

Related product manuals