26
GB/AU
HOME MODE (HO)
StartupandReset - must be carried out after a long power cut or at
rst time use.
A Startup/Reset procedure has to be performed to initiate the correct
mode and function of the heater.
IMPORTANT: there are two different startup sequences
1) If °C-17-rE is ashing in the display: go to procedure A.
2) If HO is ashing in the display: go to procedure B.
The procedure must be completed in one continuous sequence to be
valid. Should the procedure be performed incorrectly or fail, switch off
the heater and start a new reset procedure.
StartupprocedureA–iftheheaterhasbeenconnectedand
switchedonbeforehand:
On switching heater on, the sequence
°C – 17 – rE - will ash in the display.
This means that the thermostat has
been disconnected for a long period
and needs to be restarted.
To set the heater back to the factory
default, switch off the heater using the
main switch.
Press and hold in and then switch on
using the main power switch.
Continue to press until rE ashes in
the display, then release .
After a few seconds HO will ash in
the display.
You can choose between the modes
HO, OF (Ofce) and CA (Cabin) by
pressing the or key.
Conrm your choice by pressing in the
key for more than 5 seconds.
22 (°C) will ash. Select your preferred
comfort temperature.
Conrm by pressing in the key for
more than 5 seconds.
If you do nothing, 22 (°C) will auto-
matically be stored after 7 seconds.
StartupprocedureB–iftheheaterhasneverbeenswitchedon
sinceleavingthefactory:
When the heater is switched on, HO
(Home mode) will ash in the display.
You can select between modes HO, OF
(Ofce) and CA (Cabin) by pressing the
or key.
Conrm your choice by pressing in
key for more than 5 seconds.
22 (°C) will ash. Select your preferred
comfort temperature.
Conrm by pressing in the key more
than 5 seconds.
If you do nothing, 22 (°C) will auto-
matically be stored after 7 seconds.
Start nighttime temperature cutback
At the time you wish temperature cut-
back to start, press for 5 seconds.
h (hours) will ash 3 times and then
07 will ash continuously.
With the or key select the
number of hours you want the cutback
to last.
Conrm by pressing the key briey.
°C will ash 3 times and then 17 (°C)
will ash continuously.
Using the or key select the cut-
back temperature.
Conrm by pressing key briey.
The green lamp (4) will now ash
slowly to indicate that temperature
cutback is active.
The temperature is reduced for the
number of hours you have chosen.
This will be repeated for the same period every night.
Start daytime temperature cutback
At the time you wish temperature cut-
back to start, press for 5 seconds.
h (hours) will ash 3 times and then
05 will ash continuously.
Using the or key, select the
number of hours you want the tem-
perature cutback to last.
Conrm by pressing the key briey.
d will ash 3 times and then a random
number.
Using the or key, enter the cor-
rect day of the week (Monday = 1,
etc.).
Conrm by pressing the key briey.
°C will ash 3 times and then 17 (°C)
will ash continuously.
With or key select your preferred
cutback temperature.
Conrm by pressing key briey.
The green lamp (1) will now ash
slowly to indicate that temperature
cutback is active.
The temperature is reduced for the
number of hours you have chosen. This will be repeated at the same
times from Monday to Friday, leaving Saturday and Sunday unaffected.