450374 -1 www.adclaundry.com 7
Lint Drawer
The lint screen is located just below the tumbler. The lint
screen prevents lint from entering the exhaust system. The
lint screen should be kept clean at all times. Lint screens
with tears or holes should be replaced immediately. This
type lint screen should be clean after every load.
Electrical Panel
The control panel is made up of 2 motor contactors, fuse(s),
and a 24VAC transformer. The fuse(s) protect the transformer
from shorting. The transformer is used to break the incoming
voltage to 24VAC for the control voltage of the machine. The
motor contactor is used to drive the motor when the computer
applies voltage to the contactors coil.
Main Door Switch and Front Panel
The main door switch is located behind the main door on the
right-hand side. When the main door is opened, the switch
will also open preventing the dryer from operating. The main
door switch is a safety device and should never be disabled.
Lint Box, Lint Switch,
and Temperature Sensor Assembly
The lint box is located just below the tumbler. The temperature
sensor assembly is inside lint compartment on the left-hand
side. The lint switch is located at the top left front of the lint
box.
When the lint switch is opened, the dryer will not operate and
if a restart is attempted with the switch open, the computer
will display, “DOOR”.