49
3. Lithium Battery
a. Lithium Battery Replacement
1) Discontinue electrical service to the dryer.
2) Remove the battery cover which is located directly above the buss terminator on the TSX17 PLC
(Programmable Logic Controller) by sliding the cover in an upward direction.
NOTE: The lithium battery is attached to the cover and plugged into the module.
3) Remove the plug from the module, then remove the battery from the cover.
4) To install new lithium battery, reverse Step #3 thru Step #1.