46
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION and EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws, (bearing set screws), non-permanent gas connections (unions,
shut-off valves, orifices, and grounding connections). Motor and drive belts should be
examined. Cracked or seriously frayed belts should be replaced. Tighten loose V-belts when
necessary. Complete operational check of controls and valves. Complete operational check of
ALL safety devices (door switches, lint drawer switch, sail switch, burner and hi-limit
thermostats).