LYNX-R is not intended for UL985 Household Fire applications.
Introduction
This Quick Start Guide can help you install the LYNX (non-rechargeable) and LYNX-R
(rechargeable ) quickly and easily by providing the basic steps for installation using the built-in
defaults. For more detailed information and important notes, refer to the LYNX and LYNX-R
Installation Instructions.
The following steps assume that one of the system’s default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default
tables, see the Installation Instructions.
Default Table Summary
Zone Table 1 Table 2 Table 3 Table 4
1 ------- ------- ------- -------
2 front door front door front door front door
3 back door back door back door back door
4 window Garage door window window
5 motion detector motion detector window window
6 ------- smoke detector window window
7 ------- ------- window window
8 ------- ------- motion detector motion detector
9 ------- ------- smoke detector smoke detector
26 loop 3 arm away loop 3 arm away loop 3 arm away loop 3 arm away
27 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm
28 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4 close device
29 loop 1 restore device 1 loop 1 restore device 1 loop 1 restore device 1 loop 1 restore device 1
30 loop 3 arm away loop 3 arm away loop 3 arm away loop 3 arm away
31 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm
32 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4 close device
33 loop 1 restore device 1 loop 1 restore device 1 loop 1 restore device 1 loop 1 restore device 1
92 duress duress duress duress
99 silent alarm silent alarm silent alarm silent alarm
User
Code
1-2-3-4 1-2-3-4 1-2-3-4 1-2-3-4
Install
Code
4-1-1-2 4-1-1-2 4-1-1-2 4-1-1-2
Entering Program Mode:
installer code + 8 0 0
Interactive Mode Used to Program
*
56
Enhanced Zone Programming Zone characteristics, report codes, and serial numbers
*
83
Sequential Mode 5800 Series transmitter serial numbers
*84
Assign Zone Voice Descriptors Voice descriptors for each zone
Exiting Program Mode:
*
99
allows re-entry into the Program mode using Installer Code + 8 0 0.
*
98
inhibits re-entry into the Programming mode using the Installer Code.
NOTES:
•
Tables 2 and 4 support the automatic paging feature (open/close events reported to pager phone
number),and a Powerline Carrier Device programmed as device 8, which closes and stays closed
upon burglary alarms and restores after bell timeout. For other applications or actions (e.g., using a
pulsing siren), see the *80 Device Programming Menu Mode section of the Installation Instructions.
•
Primary report format for all tables is Ademco’s Contact ID reporting. Tables 2 and 4 also use Contact
ID for secondary reporting. Tables 1, and 3 use 4+1 format for secondary reporting.
•
Table 2 records all events in the event log. Tables 1, 3, and 4 record only alarms, alarm restores,
troubles, and trouble restores in their event logs.