Instruction Manual
Clockwise twist the timer knob and set the desired time. (Time Range between 0-120 minutes)
Clockwise twist hot air circulation thermostat knob and set the desired temperature, then the
temperature lights will be on. (Temperature range between 0 ~ 300 )
When the temperature reach to the fixed one, the temperature light will be off.
The electro thermal tube stops heating.When the temperature drops a little, the temperature light
turn on, the thermostat will switch on the power automatically.
Spray Lamp
6. Spray device operation
This spray device is used accompany with hot air circulation device. The spay will turn into water
vapor in the hot stove.
When using the spray function, the lowest temperature in the furnace to reach 120 degrees
Press steaming fog switch( the spray light will be on), spay into inside chamber and hit the
heating pipe through the fan, and generate hot steam.
Amount of steam depends on the time you holding down the switch, but not more than 5 seconds.
The required spray volume is based on the cooking food and the amount of food, and can be
controlled.
Remark:
This spray device is used accompany with the timer and hot
air circulation device.
5. Routine Inspection & Cleaning and Maintenance
5.1 Routine Inspection
Always conduct routine inspections. Always check the products, and serious accidents can be
avoided.
When circuit or machines at failure, stop using.
Pay attention to check the status of machines before and after use everyday.
Check and see whether the machine is tilted.Whether control panel is broken before using.
Check whether there are aging, cracked or broken wires.
Check whether there is peculiar smell,offensive smell or vibration noise.
Check and see whether temperature is under controlled, whether there is leakage
phenomenon.Whether power is normal?
5.2. Cleaning and Maintenance
Cut off the power before maintenance. Make sure the oven is cooling down
when cleaning.
Clean up residual oil and residues in oven regularly to keep the inside of oven and furnace clean.
It is not allowed to use acidic cleaner.
Removed the racks or trays from inside chamber and put into water with cleaner.And use dry
cloth to clean inside chamber first, then use wet cloth.
It is not allowed to use water to spray it directly, prevent moisture infiltration to damage electrical