ADJ Products, LLC - www.adj.com - UB 6H User Manual Page 12
UB 6H Operating Instructions
ADJ Remote Activation:
This function is used to activate and deactivate the IR sensor. When this function is activated, you
can control the fixture using either the ADJ UC IR or Airstream App. Please see the ADJ UC IR/
Airstream IR Operation section of this manual for details on controls and functions.
1. Plug the fixture in and press the MODE button until “dXX” is displayed. “XX” represents either
“on” or “oFF”.
2. Press the SET UP button until “IrXX” is displayed. “XX” represents either “on” or “oF”.
3. Press the UP or DOWN buttons to either activate the remote function (On) or deactivate it (Off).
DMX State:
This mode defines how the fixture will behave in the event that DMX signal is lost or interrupted.
It also determines the operating mode that the fixture will default to when power is applied after a
shutdown event.
1. Plug the fixture in and press the MODE button until “d.XXX” is displayed. “XXX” represents the
current DMX address.
2. Press the SET UP button so that “nodn” is displayed. Use the UP and DOWN buttons to scroll
through the DMX states.
“bLAC” (Blackout) - If the DMX signal is lost or interrupted, the unit will automatically go into
stand by mode.
“LASt” (Last State) - If the DMX signal is lost or interrupted, the fixture will stay in the last
DMX set up. If power is applied and this mode is set, the unit will automatically go into the
last DMX set up.
“ProG” (Auto Run) - If the DMX signal is lost or interrupted, the unit will automatically go into
Auto Run mode.
3. Use the UP and DOWN buttons to find your desired DMX state, then press SET UP to confirm
and exit.
Dimmer Curve:
This is used to set the dimming curve used with DMX mode. See the Dimming Curves section of
this manual for details.
1. Plug the fixture in and press the MODE button until the current DMX address is displayed.
2. Press the SET UP button until “dr-X” is displayed. “X” represents the displayed dimmer curve
(0-4).
0 - Standard
1 - Stage
2 - TV
3 - Architectural
4 - Theatre
3. Press the UP or DOWN buttons to scroll through and select your desired dimming curve.