Shutting Down (cont.)
To shut down in an emergency, press the red button on top of the
machine head. If the emergency stop button is actuated, it will need to
be unlocked by turning it anticlockwise before the machine will run
again.
3.6 Fault Diagnosis
This machine has a built in fault diagnosis. The display may show the
following:
1. H-F
If the element of the heat press, or the thermal cut-out go open
circuit, after approximately 20 minutes the display will show
“H-F”, and a buzzer will sound. If this display is seen, contact
your machine supplier immediately.
2. P-F
If the probe goes open circuit, the display will show “P-F”
immediately, and a buzzer will sound. Contact your machine
supplier immediately.
CAUTION
In all fault conditions switch off the power to the machine and unplug
the machine from the electrical supply before contacting your machine
supplier.
3.7 Hints and Tips
Transfer Printing
Extra care should always be taken to ensure that transfer paper is
placed print down onto the article, as mistakes will result in the heat
plate becoming soiled with ink and spoiling following work.
When transfer printing, it may be found advantageous to cover the
press pad with paper to prevent strike-through of surplus ink,
particularly when printing thin material as surplus print on the pressing
pad cover can also strike back on the following work.
Transfer Paper/Motifs Fail to Print Out Correctly
Check:-
1. Heat and time dwell settings are correct.