SYSTEM TROUBLE ERROR CODES
TBL
Flashes /
Touchpad beeps
READY
Flashes
Trouble Condition Action
6 NONE Lost Key Mode This is a reminder that the system has been put into the lost key mode ([STAY] &
[AWAY] pressed simultaneously). While in this mode, the system can only be dis-
armed with your EZ-IFOB. When you have replaced or re-keyed your deadbolt,
press [STAY] & [AWAY] simultaneously again to exit lost key mode.
7 NONE Fire Zone Trouble A problem has been detected with the Fire zone. Call for service.
1 1 Wireless Receiver TBL
or EZ Touchpad TBL
A problem has been detected with the wireless receiver. Call for service.
2 2 Wireless Receiver Jam A problem has been detected with a wireless receiver. Call for service.
3 2-8 Wireless Transmitter
Low Battery
The battery in a wireless transmitter is low and should be replaced. This transmit-
ter is on the zone corresponding to the number of
READY
flashes. The replace-
ment battery for the GEM-TRANS2 door/window transmitter, GEM-PIR motion
detector and GEM-GB glass break detector is the Duracell DL123A 3 Volt Lithium
(2 required for the GEM-PIR and GEM-GB). The GEM-DT Dual Technology Sen-
sor requires 4 C cell Alkaline batteries.
Warning: Replace batteries only with the same
type as specified above. Use of another battery may present a risk of fire or explosion. Do
not recharge or disassemble battery, or dispose of in fire.
4 2-8 Wireless Transmitter
Supervisory Failure
A problem has been detected with a wireless transmitter on the zone correspond-
ing to the number of
READY
flashes. Call for service.
5 1-4 Wireless Smoke
Detector Low Battery
The battery in a wireless smoke detector is low and should be replaced. The
number of the smoke detector corresponds to the number
READY
flashes. The
replacement battery is the Duracell MN1604 9 Volt Alkaline (2 required).
Warning: Replace batteries only with the same type as specified above. Use of another
battery may present a risk of fire or explosion. Do not recharge, disassemble, or dispose of
battery in a fire.
6 1-4 Wireless Smoke
Detector Supervisory
Failure
A problem has been detected with a wireless smoke detector. Call for service.