352*5$00,1*)250
Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.
Field Function Data Entries Programmable Values
SYSTEM SETUP (
20–
29)
20
INSTALLER CODE
| | | [6321]
4 digits, 0–9
21
QUICK ARM ENABLE
[1,1]
Part. 1 Part.2
0 = no; 1 = yes
22
RF JAM OPTION
[0]
0 = no RF Jam detection; 1 = send RF Jam report
UL: must be 1 if wireless devices are used
23
FORCED BYPASS
[1,1]
Part. 1 Part. 2
0 = none UL: must be “0”
1 = bypass open zones
24
RF HOUSE ID CODE
| | |
Part. 1 Part. 2 Common
00 = disable all wireless touchpad usage
01–31 = using 5827, 5827BD or 5804BD touchpad
[00,00,00]
26
CHIME BY ZONE
[0]
0 = no; 1 = yes (select zones to chime on zone list 3,
using *81 Menu mode)
27
X–10 HOUSE CODE
[0]
0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G,
7 = H, 8 = I, 9 = J, #10 = K, #11 = L, #12 = M, #13 = N,
#14 = O, #15 = P UL: not for fire or UL installations
28
ACCESS CODE FOR
4285/4286 PHONE MODULE
| [00]
(Partition 1 only)
00 = disable; 1st digit: enter 1–9; 2nd digit: enter # + 11
for "
", or # + 12 for "#".
UL: must be “00” for UL Commercial Burg. installations
29
LONG RANGE RADIO OUTPUT
[0]
0 = disable; 1 = enable
ZONE SOUNDS AND TIMING (
31 –
39)
31
ONE AUDIBLE ALARM PER ZONE
[0]
0 = no UL: must be “0”
; 1 = yes
32
FIRE ALARM SOUNDER TIMEOUT
[0]
0 = sounder stops at timeout;
1 = no sounder timeout UL: must be “1” for fire install.
33
ALARM SOUNDER TIMEOUT
[1]
0 = none; 1 = 4 min; 2 = 8 min; 3 =12 min;
4 = 16 min; UL: minimum “1” (4 min.)
34
EXIT DELAY
| | [60,60]
Part. 1 Part. 2
00–99 = seconds of exit delay time for each partition
Common zones use same delay as partition 1.
35
ENTRY DELAY #1 (zone type 01)
| | [45,45]
Part. 1 Part. 2
00–99 = seconds of entry delay #1 time for each
partition; UL: 45 seconds max.
Common zones use same delay as partition 1.
36
ENTRY DELAY #2 (zone type 02)
| | [90,90]
Part. 1 Part. 2
00–99 = entry delay #2 time for each partition;
UL: 60 seconds max.
Common zones use same delay as partition 1.
37
AUDIBLE EXIT WARNING
[1,1]
Part. 1 Part. 2
0 = no; 1 = yes
38
CONFIRMATION OF ARMING DING
[0,0]
Part. 1 Part. 2
0 = no; 1 = yes (wired touchpads and RF)
2 = yes, RF only
39
POWER UP IN PREVIOUS STATE
[1]
0 = no; 1 = yes UL: must be “1”
DIALER PROGRAMMING (
40 –
42)
Enter the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11 for '
'; #+12 for '#'; #+13 for a 2-second pause.
40
PABX ACCESS CODE
| | | | |
Enter up to 6 digits. If fewer than 6 digits are entered, exit by pressing [
] and next
desired field number. To clear entries from field, press
40
.
41
PRIMARY PHONE No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits; Do not fill unused spaces. If fewer than 20 digits entered, exit by pressing [
] and
next desired field number. To clear entries, press
41
.
42
SECOND PHONE No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits; Do not fill unused spaces. If fewer than 20 digits entered, exit by pressing [
] and next
desired field number. To clear entries, press
42
.

Other manuals for ADT Safewatch Pro 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT Safewatch Pro 3000 and is the answer not in the manual?

ADT Safewatch Pro 3000 Specifications

General IconGeneral
KeypadsSupports multiple keypads
CommunicationLandline, cellular
Remote AccessVia ADT Pulse (if subscribed)
TypeWired
Power Supplybattery backup
CompatibilityADT Monitoring Services
SensorsDoor/Window, Motion
InstallationProfessional
Backup BatteryYes

Related product manuals