Annunciation Modules
 6\VWHP 2YHUYLHZ
Unimode 400 Installation PN 50710:A 10/22/97 1-15
$QQXQFLDWRU&RQWURO6\VWHP$'7$&6
The ACS series annunciator and control system provides the Unimode 400 with up to
32 remote serially connected annunciators, each with a capacity of 64 points. Table 1-
11 contains brief descriptions of ACS annunciators. For detailed information, refer to
the ACS Manual.
Table 1-11 ADT-ACM-16AT/ADT-ACM-32A Modules
$QQXQFLDWRU)L[HG0RGXOHV
Annunciator Fixed Modules (ADT-AFM-16AT and ADT-AFM-32A) provide the
control panel with discrete display and control points. ADT-AFMs turn their LEDs on
and off as directed by the CPU, and also report switch activations to the CPU for action.
You can only use one ADT-AFM in a system. Each annunciator’s address is fixed at
address 1.
ADT-AFM-16AT – The ADT-AFM-16AT contains 16 red alarm and 16 yellow
trouble LEDs, a system trouble LED, an On-line/Power LED, and a local sounder,
and switches for control panel Acknowledge, Alarm Silence, and System Reset.
Use the ADT-AFM-16AT for systems that require 16 or fewer annunciation points.
ADT-AFM-32A – The ADT-AFM-32A contains 32 red alarm LEDs, a system
trouble LED, an ON LINE/POWER LED, and a local panel sounder with a silence/
acknowledge switch. The ADT-AFM-32A is fixed at address 1, and will not accept
expander modules.
Module Features
Annunciator Control Module-
16AT (ACM-16AT)
The ADT-ACM-16AT provides features for audible and
visual indication of alarm and trouble conditions at each
annunciator. These features include: 1) 16 red alarm
LEDs; 2) 16 yellow trouble LEDs; 3) 16 momentary touch-
pad switches for controlling each point; 4) a system trouble
LED; 5) an On-line/Power LED; 6) a local sounder; 7) a
Silence/Acknowledge switch; and remote functions.
Annunciator Expander Module
(AEM-16AT)
The AEM-16AT, identical in size and appearance to the
ACM-16AT, expands the ADT-ACM-16AT by 16 system
points. An ADT-ACM-16AT can support up to three
AEM-16ATs, to a provide a maximum of 64 system points.
1RWH
$Q $(0$7 FDQQRW EH XVHG WR H[SDQG DQ $&0$
Annunciator Control Module-
32AT (ADT-ACM-32A)
The ADT-ACM-32A provides features for audible and
visual indication of alarm and trouble conditions at each
annunciator. These features include: 1) 32 red alarm
LEDs; 2) a system trouble LED; 3) an On-line/Power LED;
4) a local sounder; and 5) a Silence/Acknowledge switch.
Annunciator Expander
Module-32A (AEM-32A)
The AEM-32A, identical in size and appearance to the
ADT-ACM-32A, expands the ADT-ACM-32A by 32
system points. An ADT-ACM-32 can support one AEM-
32A, providing a maximum of 64 system points. Note:
An AEM-32A cannot be used to expand an ADT-ACM-
16AT.

Related product manuals