7DEOH RI &RQWHQWV
3. Testing the System
vi Unimode 400 Installation PN 50710:A 10/2297
Style 6 Wiring Diagram...................................................................................2-46
Style 7 Wiring Overview .................................................................................2-47
Style 7 Wiring Diagram...................................................................................2-47
Wiring an Isolator Module (M500X)...................................................................2-48
M500X Overview ............................................................................................2-48
Isolating a Branch of a Two-Wire SLC...........................................................2-48
Wiring an IDC with M500M Modules.................................................................2-49
Overview of Monitor Modules (M500M Series).............................................2-49
Wiring an M500M Module..............................................................................2-49
Wiring an NFPA Style B IDC with M500Ms.................................................2-50
Wiring an NFPA Style B IDC with M502Ms.................................................2-51
Wiring an NFPA Style B IDC with M500Ms................................................2-52
Wiring a NFPA Style D IDC with M502M Modules......................................2-53
Wiring a Notification Appliance Circuit (NAC) or Control Circuit....................2-54
M500CH Module Overview ............................................................................2-54
Testing an M500CH Module...........................................................................2-54
Installing an M500CH as a Form-C Relay ......................................................2-55
SLC Wiring with M500CH Modules...................................................................2-55
Style Y NAC Circuits (Two-Wire)..................................................................2-56
Wiring Diagram and Instructions.....................................................................2-56
Style Z NAC ....................................................................................................2-57
Style Z NAC Circuits (Method 1 – MPS-400 powers M500CH)....................2-58
Style Z NAC Circuits (Method 2 – MPS-400 powers M500CH)....................2-59
SLC Wiring with an Intelligent Detector.............................................................2-60
Overview for Wiring Intelligent Detectors......................................................2-60
Wiring a B501B Detector to an SLC Loop......................................................2-60
SLC Wiring with an ADT-BGX-101L Addressable Manual Pull Station...........2-61
ADT-BGX-101L Overview.............................................................................2-61
ADT-BGX-101L Wiring Connections ............................................................2-61
7HVWLQJWKH6\VWHP
Acceptance Test
........................................................................................................3-1
Periodic Testing and Service
...................................................................................3-1
Operational Checks
..................................................................................................3-1
Test Modes
Walk Test Mode.....................................................................................................3-2
Live Test Mode ......................................................................................................3-3
Battery Checks and Maintenance
...........................................................................3-4
9RLFH$ODUP6\VWHP
Section Overview
......................................................................................................4-1
Installing an AMG
Configuring the AMG............................................................................................4-4
AMG-1 and AMG-E Tone/Message Selections (SW2=Off).................................4-5
AMG-1 and AMG-E Tone/Message Selections (SW2=On)..................................4-6
ATG-2 Terminal Connections................................................................................4-7
Installing a Fire Fighter’s Telephone (FFT-7 and FFT-7S)
Overview................................................................................................................4-8
Mounting an FFT-7/FFT-7S ..................................................................................4-8
Connecting an FFT-7/FFT-7S................................................................................4-9
Installing Audio Amplifiers (AA-30/AA-100/AA-120)
Installing an AA-30..............................................................................................4-10
Overview..........................................................................................................4-10
Mounting an AA-30.........................................................................................4-10
AA-30 Terminals and Connectors...................................................................4-11
Installing an AA-100/AA-120..............................................................................4-12
Overview..........................................................................................................4-12