5.3 Customising the Input Alert Message
The default input alert message is ‘>INPUTX ACTIVE’. This can be customised by the user
using the CUSTOM command for each input. The maximum length of the message is 127
characters and it must end with a full stop. The custom command is used as follows:
CUSTOMA THE GATE IS OPEN. customised A message
CUSTOMB THE PUMP HAS STOPPED PLEASE CALL 07000000000. customised B message
Custom1 the voltage is outside the specified limits. analogue input 1 message
Use only text or number characters in the message. The message will end where there is a
full stop. Do not use a full stop in the middle of the message. If you do not specify the
channel the message is applied to channel A.
Separate messages can be specified for when the channel is triggered by a positive going
(logic HIGH) edge or a negative going edge (LOW). This is achieved by adding the appro-
priate suffix to the command (this is particularly useful when INLEVEL is set to BOTH:
CUSTOMAH this is sent when input A goes positive.
CUSTOMBL this is sent when input B goes negative.
When setting analogue channel customised messages the over-voltage message is set
using the H (high) suffix. Similarly when setting the under voltage limit the L (low) suffix is
used.
Custom2H this is the an2 channel over-voltage message
custom2L this is the an2 channel under-voltage message
5.4 Autodial Logic
By default, if both inputs are set to autodial, then if either input is triggered dialling will com-
mence (OR configuration). If desired the system can be set to require both inputs to be in
the active state in order to initiate dialling (AND configuration). Additionally the system can
be set for input A to be triggered before input B (A THEN B) in order to initiate dialling. To
change the autodial logic settings the following message is sent to the board:
autodial AND requires both inputs to be active to initiate dialling
autodial OR triggering either input initiates dialling
AUTODIAL THEN A THEN B triggering
aut A
aut o
Aut T
5.5 Changing the Maximum Ring Time
The maximum time for which the system will attempt dialling before dialling the next num-
ber is set using the RTIME command. The default time limit is 60s. The RTIME command is
specified in seconds and can be set from 1s to 255s. Most calls will require at least 15s for
connection which is included in RTIME.
RTIME 45. sets the maximum ring time to 45 seconds

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Advent Controls X5 Series and is the answer not in the manual?

Advent Controls X5 Series Specifications

General IconGeneral
BrandAdvent Controls
ModelX5 Series
CategoryGSM/GPRS Modules
LanguageEnglish

Related product manuals