Installation – for qualied contractors
Fitting the cable grommet
26_02_02_0950
» Fit the cable grommet. For connecting cables
> 6 mm², enlarge the hole in the cable grommet.
Making the water connection
!
Material losses
Carry out all water connection and installation work
in accordance with regulations.
26_02_02_0948
» Seal and insert the twin connectors.
!
Material losses
Never use the shut-off valve in the cold water inlet
to reduce the ow rate.
Preparing the back panel
!
Material losses
If you break out the wrong knock-out by mistake, use
a new back panel.
L
L
L
D0000041893
» Break out the cable grommet knock-out in the
back panel. Deburr the sharp edges with a le if
necessary.
Installing the appliance
L
L
L
3
L3’
4
L2’
1
L1’
2
L
L
L
MV
NT C
T- soll
X1 1
D0000041894
» Push the back panel over the threaded stud and the
cable grommet. Pull the cable grommet by the lock-
ing hooks into the back panel using pliers, until both
locking hooks audibly click into place.
» Remove the transport plugs from the water
connections.
» Push the back panel rmly against the wall. Lock the
xing toggle by turning it 90° clockwise.
D0000041925
» Screw the water connection pipes with at gaskets
onto the twin connectors.
!
Material losses
The strainer must be tted for the appliance to func-
tion.
» When replacing an appliance, check whether
the strainer is installed (see chapter "Installa-
tion / Maintenance").