EasyManua.ls Logo

AEG DDLE Basis 11 - Installation

AEG DDLE Basis 11
76 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
Installation – for qualied contractors
Note
» Mount the appliance on the wall. The wall must
have a sufcient load-bearing capacity.
9.2 Water installation
A safety valve is not required.
» Flush the water line thoroughly.
» Ensure that the ow rate for switching on the appli-
ance is achieved (see chapter "Installation / Spec-
ication / Data table", On). If the ow rate is not
achieved, remove the ow limiter (see chapter "In-
stallation / Installation, Removing the ow limiter").
» If the required ow rate is not achieved when the
draw-off valve is fully opened, increase the water line
pressure.
Taps
Use appropriate pressure taps. Open taps are not per-
mitted.
Note
Never use the shut-off valve in the cold water inlet to
reduce the ow rate. The shut-off valve is intended
to shut off the appliance.
Permissible water line materials
Cold water inlet line:
Galvanised steel pipe, stainless steel pipe, copper
pipe or plastic pipe
DHW outlet line:
Stainless steel pipe, copper pipe or plastic pipe
!
Material losses
If plastic pipework is used, take into account the
maximum inlet temperature and the maximum per-
missible pressure (see chapter "Installation / Spec-
ication / Data table").
Flexible water connection lines
» If the appliance is installed with exible water con-
nection lines, ensure that the bayonet ttings of
the pipe bends do not become twisted inside the
appliance.
» Secure the back panel at the bottom with two addi-
tional screws.
10. Installation
10.1 Standard installation
Electrical connection from above; installation on un-
nished walls
Water connection on unnished walls
DDLE Basis 18/21/24: Connected load 21 kW preset
For further installation options, see chapter "Installation /
Installation / Installation options":
Electrical connection from below on unnished walls
Electrical connection on nished walls
Connecting a load shedding relay
Undersink installation, water connections from above
Water installation on nished walls
Operation with preheated water
Temperature limit
Opening the appliance
D0000041615
» Open the appliance by releasing the snap lock.
NT
T-
so
X1
26_02_02_0762
» Remove the back panel by pressing the two locking
hooks and pulling the lower section of the back panel
forwards.
Preparing the power cable
160
≥ 30
26_02_02_0887
Fitting the wall mounting bracket
26_02_02_0972
» Mark out the holes for drilling with the installation
template. If the appliance is to be installed with water
connections on nished walls, also mark out the x-
ing holes in the lower part of the template.
» Drill the holes and secure the wall mounting bracket
with 2 screws and 2 rawl plugs (screws and rawl
plugs are part of the standard delivery).
» Fit the threaded stud provided.
» Mount the wall mounting bracket.

Table of Contents