EasyManua.ls Logo

AEG DDLE Basis 11 - User Manual

AEG DDLE Basis 11
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DDLE Basis 11
DDLE Basis 13
DDLE Basis 18
DDLE Basis 18/21/24
DDLE Basis 27
Elektronisch gesteuerter Durchlauferhitzer
Bedienungs- und Installationsanleitung
...........................2
Electronically controlled instantaneous water heater
Operating and installation instructions
..........................18
Elektronicznie sterowany przepływowy
ogrzewacz wody
Instrukcja obsługi i instalacji
.................................................34
Проточные водонагреватели с электронным
управлением
Инструкция по эксплуатации и установке
...........48
Електронски управуван проточен бојлер
Упатство за ракување и инсталација
.......................64

Other manuals for AEG DDLE Basis 11

Questions and Answers

  • A
    Angel KramerAug 13, 2025
    How to fix AEG Water Heater when it doesn't start despite the tap being fully open?
    • M
      Mario DavisAug 13, 2025
      If the heating system in your AEG water heater doesn't start even when the tap is fully open, here's what you can check: * **No voltage:** Inspect the fuses in your fuse board. * **Start-up volume not reached:** Clean and descale perlators in water taps or shower heads, as contamination or scaling may be the cause. * **Faulty heating system:** Call a service technician to test the heater and replace it if necessary.
  • K
    Kiara BaileyAug 17, 2025
    How to increase the flow rate of my AEG DDLE Basis 11 Water Heater?
    • J
      jamescarrilloAug 17, 2025
      If the flow rate of your AEG water heater is too low, it might be caused by scaled up shower head/perlators or contamination. Descale and replace them if required. Also, clean the sieve.
  • V
    Victoria HernandezAug 20, 2025
    What to do if my AEG DDLE Basis 11 Water Heater has no hot water and no “traffic light” display?
    • C
      Connor SmithAug 21, 2025
      If your AEG water heater isn't producing hot water and the traffic light display is off, here are a couple of things to check: * **Fuse/MCB:** Verify the fuse/MCB in your fuse box and replace if necessary. * **Safety pressure limiter:** If the safety pressure limiter has tripped, remove the cause of the fault. Open the downstream tap for 1 minute to depressurize and cool down the heating system. Then, press the pushbutton on the safety pressure limiter. If the issue persists, test the electronics PCB and replace if required.
  • R
    Robert BaxterAug 25, 2025
    Why my AEG DDLE Basis 11 Water Heater set temperature is not achieved?
    • J
      Jamie CarterAug 25, 2025
      If your AEG water heater isn't reaching the set temperature, it could be due to one phase being down. Check the fuse/MCB in the fuse box.
  • K
    knoxjustinAug 27, 2025
    What does it mean if my AEG Water Heater has no hot water, throughput is > 3 l/min, and the traffic light displays constant yellow with green flashing?
    • J
      jessezunigaAug 27, 2025
      If your AEG water heater shows these symptoms, consider the following possible causes: * The high limit safety cut-out may be triggered, so check and activate it if needed. * There could be a cable break. * The heating system might be faulty, so test the heating system resistor and replace if necessary. * Faulty electronics could also be the cause, so test the electronics PCB and replace if required.
  • L
    laurenmurraySep 1, 2025
    What to do if my AEG Water Heater has no hot water, throughput > 3 l/min, and the traffic light displays green flashing or constantly ON?
    • A
      andersonkimSep 1, 2025
      If your AEG water heater exhibits these symptoms, it could be due to: * Faulty electronics, so test the electronics PCB and replace if necessary. * The flow sensor DFE might not be plugged in, so refit the plug of the electronics PCB. * The flow sensor DFE could be faulty, so check and replace the flow switch if required.
  • T
    Tony ScottSep 4, 2025
    Why does my AEG DDLE Basis 11 Water Heater not switch on and there is no hot water?
    • T
      Timothy CoffeySep 4, 2025
      The air sensor may be detecting air in the water, causing the AEG water heater to switch off briefly. The device should restart after one minute.
  • J
    Jonathan RichardsSep 8, 2025
    Why does my AEG DDLE Basis 11 show constant red illumination and green flashing with no hot water?
    • B
      Brooke JonesSep 8, 2025
      If your AEG water heater displays these symptoms, check the following: * The cold water inlet temperature might be above 35 °C. Reduce the temperature of the cold water supply. * The flow rate might be greater than 25 l/min. Reduce the device throughput. * The cold water sensor could be faulty. Test the electronics PCB and replace if required.

Summary

Operating Instructions

Vital Facts in Brief

Provides concise information on temperature selection and limits.

Safety Information

Highlights risks of scalding and supervision requirements for user safety.

DHW Output

Details domestic hot water output capacities based on water temperatures.

Installation Instructions

Important Information

Warns about air in the water supply and the heater's air detection system.

Instructions and Regulations

Stresses adherence to qualified installation and local regulations.

Standard Installation for Contractors

General Installation Information

Covers factory setup, installation suitability, and load changeover.

Water Connection

Instructs on connecting water lines and flushing the supply line.

Power Supply

Covers connecting the power cable to the terminal strip and earthing.

Commissioning

Outlines the procedure for initial setup, venting, and testing by a contractor.

Alternative Installation Methods

Temperature Limit

Explains setting a permanent maximum outlet temperature of 43 °C.

Specification and Application Areas

Troubleshooting by the User

Troubleshooting by the Contractor

AEG DDLE Basis 11 Specifications

General IconGeneral
BrandAEG
ModelDDLE Basis 11
CategoryWater Heater
LanguageEnglish

Related product manuals