10
For the tter
2.6 Maintenance
The outside of the storage heater does not require any special maintenance. To clean, wipe using a
soft cloth or damp sponge only. Do not use any abrasive agents or aggressive detergents.
Caution! Always fully disconnect the appliance from the power supply before carrying out any
maintenance work.
To ensure a long service life, it is recommended to have a specialist technician inspect the
anti-corrosion anode (magnesium anode) in the appliance once per year. This check may need to be
carried out more frequently in areas with particularly aggressive water – ask the tter or your local
water supply company for information.
The appliance is protected against overheating by a safety temperature limiter which interrupts
all phases. If the safety temperature limiter has been triggered, an authorised specialist technician
is required to carry out the repair work. The high limit safety cut-out can be reset by pressing the
pushbutton (marked Safety) on the controller below the control panel cover.
2.7 Technical specications
!
Type EWH Basis
30 / 30 N
EWH Basis
50 / 50 N
EWH Basis
80 / 80 N
EWH Basis
100 / 100 N
EWH Basis
120 / 120 N
EWH Basis
150 / 150 N
EWH Basis
200 / 200 N
Rated voltage W 1/N/PE ~ 230V
Power consumption W 2000 2000 2000 2000 2000 2000 2200
Nominal capacity Litres 30 50 80 100 120 150 200
Power consumption
in stand-by mode
kWh/
d
0.73
0.93
1.16
1.48
1.71
2.01
2.90
Drawable quantity
of mixed water
at 40 °C
(1)
Litres
56,2
101,5
144,3
186
227,9
291
385,3
Weight (empty) kg 16 21 26 30 34 41 50
Weight (wet) kg 46 71 106 130 154 191 250
Dimensions A mm 100 100 100 100 100 100 100
Bmm296296274274274274274
Cmm47472828282828
Dmm390390470470470470470
Emm53059158373588911251425
Hmm585840810962111613521652
Imm102296255255255255255
Kmm386386485485485485485
Mmm78787575757575
XmmG 1/2G 1/2G 3/4G 3/4G 3/4G 3/4G 3/4
Permissible opera-
ting pressure
MPa 0,6
Degree of protec-
tion
Protection against water jets (IP 25)
Mark of conformity See rating plate
(1)
Cold water inlet 15 °C and cylinder temperature 65 °C