Set-up of the System Security:
¾ Enter the master code and validate it with the „*“-button.
¾ Enter „70“ and validate with the „#“-button.
¾ Now the keypad is blocked for the next 30 seconds after a false code was entered 10 times
consecutively.
¾ Enter „71“ and validate with the „#“-button.
¾ Now the keypad activates the DURESS OUTPUT contact after a false code was entered 10 times
consecutively. To unblock the keypad again you need a user code 1.
¾ Enter „72“ and choose a number of tolerable successive false entries between „ 5 – 10“.
¾ Validate it with the „#“-button.
¾ In according to this number the keypad is blocked after another false entry for 15 minutes. You can
adjourn this safety-catch untimely by using the master code.
¾ Enter „76“ and validate it with the „#“-button.
¾ Now you can enter an unlimited number of false codes without the consequence of blocking the keypad.
To switch on or off the Door Contact Alarm:
¾ Enter the master code and validate it with the „*“-button.
¾ Enter „80“, choose „1“ and validate it with the „#“-button.
¾ Now the acoustic alarm is activated.
¾ Enter „80“, choose „0“ and validate it with the „#“-button.
¾ Now the acoustic alarm is deactivated.
To switch on or off the Opening Signal:
¾ Enter the master code and validate it with the „*“-button.
¾ Enter „81“, choose „1“ and validate it with the „#“-button.
¾ Now the opening signal is activated. It sounds every second when the exit lock is activated.
¾ Enter „81“, choose „0“ and validate it with the „#“-button.
¾ Now the opening signal is deactivated.
Automatic or Manual User Code Entry:
¾ Enter the master code and validate it with the „*“-button.
¾ Enter „82“, choose „1“ and validate it with the „#“-button.
¾ Now the auto-entry-mode is activated. If the user code has the same number of digits as the master
code the validation of the user code by pressing the „#“-button is not required anymore when opening
the door.
¾ Enter„82“, choose „0“ and validate it with the „#“-button.
¾ Now the manual-entry-mode is activated. The use of the „#“-button for validation of the user code is
required when opening the door.
To switch on or off the Key Actuation Signals:
¾ Enter the master code and validate it with the „*“-button.
¾ Enter„83“, choose „1“ and validate it with the „#“-button.
¾ Now the keypad actuation signals are activated. They sound every time you hit a key.
¾ Enter „83“, choose „0“ and validate it with the „#“-button.
¾ Now the keypad actuation signals are deactivated.
Programming of the Time-invariance Alarm of the DOOR SENS-Function:
¾ Enter the master code and validate it with the „*“-button.
¾ Enter „9“ and choose a span of time between „1 – 999“ seconds.
¾ Validate it with the „#“-button.
¾ Now the time-invariance alarm is activated. It always sets off the alarm when the door is open for a
longer time then it is allowed by programming .
¾ Enter „9“, choose „0“ and validate it with the „#“-button.
¾ Now the time-invariance alarm is deactivated.
You can leave or close the programming mode by using the „*“-button.