MP2C
Manuale operativo - Operating manual MO.MP2C.518
Pag. 18
DELTA 1
HYSTERESIS 1
Valori Impostabili: 0000 ÷ 9999
NNNN = valore
Descrizione:
Determina il valore di disattivazione del Set Point 1.
Val.disattivazione = (val. Set Point 1 - val. Delta Point 1). Viene
disattivata l’uscita a relay SP1 e viene spento il led in
corrispondenza all’indicazione grafica SP1.
Selectable values: 0000
÷
9999
NNNN = value
Description:
To calculate set point 1 disconnection value.
Disconnection value = (Set Point 1 value - Hyster. 1 value). SP1
relay output is disconnected and the led which is just next to the
graphic indication SP1 is switched off.
HySt 1
ENTER
NNNN
Come Impostare il Parametro:
1) ESC = esce dal menu senza modificare il parametro.
2) §¨ = sposta il cursore lampeggiante sulla cifra da modificare.
3) © = incrementa la cifra selezionata dal cursore lampeggiante.
4) ENTER = memorizza il dato; mostra il passo successivo.
How to set parameters:
1) ESC = to exit from menu without modifing the parameter.
2) §¨ = to set flashing cursor on the digit to be modified.
3) © = to increase the digit selected by flashing cursor.
4) ENTER = to store the data; to display next step.
Per continuare la programmazione dei successivi
SET POINT e dei relativi DELTA, scorrere il menu
con il tasto ENTER.
To continue the programming of following set
points and corresponding hysteresis, scroll the
menu through ENTER key.