8
Aermec. 16.01. 5140901_01
4. OPERATING LIMITS
Unit Operating speed - FK260 FK360
General data
Refrigerating power - W 2700 3650
Input power - W 782 1030
Input current - A 3,5 4,6
EER (2) - W/W 3,45 3,54
SEER - - 5,2 5,4
Energy efficiency class (1) - - A A
Annual electric consumption - kWh/annum 182 240
Air flow rate maximum m/h 400 480
Air flow rate medium m/h 360 430
Air flow rate minimum m/h 320 380
Moisture removed - L/h 1,00 1,60
Power supply - - 220-240V~50Hz 220-240V~50Hz
Power cord - -
H05VV-F 300/500V 3G1,0mm
L= 1,50m + Schuko Plug
Protection rating - - IPX4 IPX4
Coolant gas - Type R32 R32
GWP - kgCO2eq. 675 675
Filling coolant gas - kg 0,51 0,63
Nominal input power (3) - W 1100 1300
Nominal input power (3) - A 5,5 6,5
Inner side
Fans - Type Centrifugal Centrifugal
Fan power - W 60 60
Evaporator - Type Copper aluminium Copper aluminium
Evaporator attachment diameter - mm Ø7 Ø7
Sound pressure (4) maximum dB(A) 50 50
Sound pressure (4) medium dB(A) 48 48
Sound pressure (4) minimum dB(A) 46 46
Sound power maximum dB(A) 59 59
Sound power medium dB(A) 57 57
Sound power minimum dB(A) 55 55
Outer side
Compressor - Type Rotary Rotary
Condenser - Type Copper aluminium Copper aluminium
Condenser attachment diameter - mm Ø7 Ø7
Fan - Type Axial Axial
Air flow rate - m
3
/h 800 1200
Sound pressure maximum dB(A) 56 58
Sound pressure medium dB(A) 54 56
Sound pressure minimum dB(A) 52 54
Sound power maximum dB(A) 65 65
Sound power medium dB(A) 63 63
Sound power minimum dB(A) 61 61
Unit dimensions
Height - mm 375 428
Width - mm 560 660
Depth - mm 710 700
Weight - kg 43 50
Transport packaging dimensions
Height - mm 425 505
Width - mm 623 739
Depth - mm 806 793
Weight - kg 47 54
Cooling (EN-14511 and EN-14825)
Ambient air temperature 27°C D.B. / 19°C W.B. Outside air temperature 35°C; Max. speed
(1) Data in accordance with Delegated Regulation (EU) No. 626/2011
(2) EER in accordance with Standard EN-14511, declared only for the purpose of the tax exemptions in force upon the creation of this publication
(3) The Nominal Input Power (Nominal Input Current) is the Maximum Input Electrical Power (Maximum Input Current) from the system, in accordance with the Standards
EN-60335-1 and EN-60335-2-40
(4) Sound Pressure measured in a semi anechoic chamber at a distance of 1,5m from the front of the unit
FK operating limits
Inner side Outer side
Dry bulb (°C) Wet bulb (°C) Dry bulb (°C) Wet bulb (°C)
Cooling in standard conditions 27 19 35 -
Maximum cooling 32 23 43 -
Minimum cooling 21 15 16 -
The safety devices can prevent the unit from operating beyond these limits.
5. TECHNICAL DATA