23
ELECTRICAL DATA 460V360HZ  FAN J
460V-3-60Hz - Fan J
Units
Total consumption
L.R.A. F.L.A. MOP Recommended fuse Phases
Mod. Comp. Fan
NRB Vers. (n°) (n°) (A) (A) (A) (n°) (n°)
0800
A 4 4 291 129 156 150 3
E 4 6 299 137 164 150 3
U 4 6 299 137 164 150 3
N 4 8 307 145 171 150 3
0900
A 4 4 341 139 169 150 3
E 4 6 349 147 177 150 3
U 4 6 349 147 177 150 3
N 4 8 357 154 185 175 3
1000
A 4 6 357 155 185 175 3
E 4 6 357 155 185 175 3
U 4 6 357 155 185 175 3
N 4 8 365 163 193 175 3
1100
A 4 6 413 181 223 200 3
E 4 8 421 189 231 225 3
U 4 8 421 189 231 225 3
N 4 10 429 196 238 225 3
1200
A 4 6 432 204 246 225 3
E 4 8 440 212 254 225 3
U 4 8 440 212 254 225 3
N 4 10 448 220 262 250 3
1400
A 4 6 484 233 287 250 3
E 4 8 492 240 295 250 3
U 4 8 492 240 295 250 3
N 4 10 500 248 303 250 3
1600
A 4 8 521 266 320 300 3
E 4 10 529 273 328 300 3
U 4 10 529 273 328 300 3
N 4 12 537 281 336 300 3
1800
A 4 8 632 307 380 350 3
E 4 12 648 323 396 350 3
U 4 12 648 323 396 350 3
N 4 14 656 331 404 350 3
2000
A 4 10 666 352 425 400 3
E 4 12 674 360 433 400 3
U 4 12 674 360 433 400 3
N 4 14 682 368 441 400 3
2200
A 5 10 699 370 443 400 3
E 5 14 715 385 458 450 3
U 5 14 715 385 458 450 3
N 5 16 723 393 466 450 3
2400
A 6 12 655 390 445 400 3
E 6 14 663 398 452 400 3
U 6 14 663 398 452 400 3
N 6 16 671 406 460 450 3
2600
A 6 14 774 440 513 500 3
E 6 16 782 447 520 500 3
U 6 16 782 447 520 500 3
N 6 18 790 455 528 500 3
2800
A 6 14 800 477 550 500 3
E 6 16 808 485 558 500 3
U 6 16 808 485 558 500 3
N 6 18 816 492 565 500 3
3000
A 6 14 826 514 587 500 3
E 6 18 842 529 602 500 3
U 6 18 842 529 602 500 3
N 6 20 849 537 610 600 3
L.R.A. Peak current from unit
F.L.A. Maximum current from unit
Earth Earth wire to connect to unit
IL Master switch