VENTILATION FAN
MODEL: AP120-S & AP120H-S
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING:
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or
telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switching on accidentally. If the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be
done by a licensed person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and
standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent backdraft. Follow the heating equipment manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or
shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit (ceiling installation only). 8. This unit
must be grounded. 9. Never place a switch where it can be reached from a tub or shower. 10. Not for use in kitchens. This unit may
be installed in a wall for a non- wet application. 11. Install fan at least 2.5 m (8 feet) above the floor. 12 WARNING: To reduce the risk
of fire or electric shock, do not use this fan with any solid-state speed control device. 13. The fan must not be installed in a ceiling
thermally insulated to a value greater than R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up for wall
application.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall and construction dust off power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance, lower or remove grille and vacuum interior of unit with the
dusting brush attachment. The motor is permanently lubricated and never needs oiling.
OPERATION
Use an on/off switch to operate this fan. See “Connect Wiring” for details.
The humidity control and fan can be operated separately. Use a 1- or 2- function wall control. Do not use a dimmer switch
to operate the humidity control. See “Connect Wiring” for details.
SENSOR OPERATION FOR AP120H-S
The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable)
increases in humidity or (b) humidity above a user-adjustable set-point (50%-100% relative humidity). The humidity sensor
may occasionally turn the fan ON when environmental conditions change. If the fan continuously responds to changing
environmental conditions, “H” (means “humidity”) adjustment may be required. This figure is factory-set for about 75% RH.
SENSITIVITY ADJUSTMENT
The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness
control, the “H” may need to be increased toward maximum “+”. If the control is responding too often to changing
environmental conditions, movement toward less “-” “H” may be required.
To adjust the “H”:
1. Disconnect power at service entrance.
2. Through the grille, locate the slot marked “H”.
3. Carefully rotate the “H” adjustment toward “+” or “-”.
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on.
5. Repeat above steps if necessary.
When the temperature changes, humidity sensor values will have deviation.
TIMER ADJUSTMENT
The humidity sensing fan has a “T” (means timer) that can be adjusted from 5 to 60 minutes (factory-set at about 20 minutes).
This “T” controls the length of time that the fan remains ON after the sensor has stopped sensing a rise in humidity
and the humidity level is below the user-adjustable set-point. To adjust the “T”:
1. Disconnect power at service entrance;
2. Through the grille, locate the slot marked “T”;
3. Carefully rotate the “T” adjustment to desired setting (from 5 to 60 minutes).
4. Check operation by turning on a humidity source until the fan turns on.
5. Turn humidity source off and time the unit.
6. Repeat above steps if necessary.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner
Question and Answer IconNeed help?

Do you have a question about the aero pure AP120H-S and is the answer not in the manual?

aero pure AP120H-S Specifications

General IconGeneral
Brandaero pure
ModelAP120H-S
CategoryFan
LanguageEnglish

Summary

Safety Warnings and Precautions

General Warning

User must read and follow all safety instructions to reduce risk of fire, electric shock, or injury.

Cautionary Notes

General use, installation, and maintenance precautions to ensure safe operation and prevent damage.

Cleaning and Maintenance

Fan Operation

Sensor Operation

Explains the humidity sensor's response to changes in humidity levels for automatic fan activation.

Sensitivity Adjustment

Guide to adjusting the humidity sensor's sensitivity ('H') for optimal performance in various conditions.

Timer Adjustment

Instructions for setting the fan's run time ('T') after humidity levels return to normal.

Installation Plan

Installation Location

Guidance on avoiding cooking areas and proper placement relative to framing.

Ductwork Connection Methods

Illustrates two ways to connect ductwork to the factory-shipped unit, including necessary components.

Assembly Instructions

Component Identification

Lists screws and hanger bars needed for installation with their dimensions.

Mounting with Joists

Detailed steps for mounting the fan housing to ceiling joists using hanger bars and screws.

Mounting with Hanger Bars Only

Instructions for attaching the fan using only hanger bars, fitting them to framing width.

Mounting to I-Joist

Specific steps for installing the fan housing and hanger bar onto an I-joist.

Ductwork Installation

Duct Connection and Routing

Guidance on connecting round ductwork, ensuring airtight seals, and optimizing duct runs for performance.

Electrical Wiring

Wiring for AP120-S

Wiring diagram and instructions for connecting the AP120-S model to the power supply.

Wiring for AP120H-S

Wiring diagram and instructions for connecting the AP120H-S model with humidity sensor.

Grille Installation

Attaching the Grille

Steps for securing the grille assembly to the fan housing using spring clips.

Service Parts

Parts List

List of all replaceable parts for the fan, including quantity and part numbers.

Blower Assembly Replacement

Instructions for replacing the blower assembly, including safety warnings.

Warranty Information

Warranty Coverage

Details the 72-month warranty period for mechanical and electrical parts against defects.

Exclusions from Warranty

Lists conditions and damages not covered by the product warranty.