DURATI battery-powered shearing machine
10
6.1 Cleaning/Disinfection
Note
Always follow disposal and hygiene instructions and
regulations!
Manual cleaning/disinfection
¾ Wipe the shell of the product with a lint-free cloth
moistened with a commercial disinfectant for wipe
disinfection.
¾ If necessary, after the appropriate exposure time,
wipe off any residues of the cleaning/disinfecting
agent with a lint-free cloth moistened with clean
water.
¾ Dry the product with a clean, lint-free cloth.
¾ Clean the contacts in the charging bay with isopro-
panol or ethyl alcohol and a cotton swab. Do not
use corrosive chemicals.
¾ If necessary, repeat the cleaning/disinfecting pro-
cess.
6.2 Control, care and inspection
¾ Allow the product to cool down to room tempera-
ture.
¾ Inspect the product after each cleaning and disin-
fecting cycle to be sure it is clean, functional and
undamaged.
¾ Lubricate the shearing head as appropriate, see
Lubricating the shearing head.
¾ Check the product for any damage, atypical run-
ning noise, overheating or excessive vibration.
¾ Inspect the shearing head for broken, damaged or
blunt cutting edges.
¾ Set aside the product if it is damaged.
7. Maintenance
To ensure reliable operation, Aesculap recommends
servicing the product at least once a year.
Service addresses
Albert Kerbl GmbH
Felizenzell 9
84428 Buchbach / Germany
Phone: +49 (0) 8086 933-100
Fax: +49 (0) 8086 933-500
Email: info@kerbl.com
www.kerbl.com
Other service addresses can be obtained from the
address indicated above.
DANGER
Risk of electric shock and fire haz-
ard!
¾ Unplug the device before clean-
ing.
¾ Ensure that no fluids will pene-
trate the product.
¾ Leave the product exposed to
air for at least 1 minute after
cleaning/disinfecting.
CAUTION
Damage to the product due to
incorrect cleaning or inappropriate
cleaning/disinfecting agents!
¾ Use any commercial detergent
for surface cleaning.
¾ Never immerse the product in
water or detergent.
¾ Do not introduce any fluid into
the charging bays.
¾ Clean the contacts in the charg-
ing bays, applying extreme care.