PF3000 Cotton Yield Monitor
Calibrating Distance
Ag Leader Technology
March 2002
3
-
14
Introduction
You must calibrate distance for a primary or secondary speed setting of
WHEEL, TRACK or RADAR.
Distance
Calibration
To view the distance calibration screen press the:
Screen
MENU key
CAL key
DISTANCE key
Choosing Speed
Sensor
You must choose the speed sensor you are using for ground speed before
you can calibrate distance. Use the UP or DOWN ARROW key to select
either:
WHEEL
TRACK
RADAR
Press the ENTER DISTANCE key after you have set the ground speed
sensor.