Summary
of
P
ages
Figure
2-5
sho
ws
all
displa
y
pages.
Eac
h
summary of
each
page is
sho
wn b
elow.
MEAS
DISPLA
Y
(under
4
DISPLA
Y
F
ORMA
T
5
)
This
displa
y
page
pro
vides
the
measuremen
t
result information,
and
con
trol
settings are
entered
from this
page. The
4284A
measures
the
device
under
test
from
this
page,
and
displa
ys
the
measuremen
t
results
in
large
c
haracters.
BIN
No.
DISPLA
Y
(under
4
DISPLA
Y
F
ORMA
T
5
)
This
displa
y
page
pro
vides
the
bin
sorting
result
information,
the
measuremen
t
results,
and
comparator function
on/o settings.
The
4284A
measures the
device
under
test
from
this
page.
The
bin
n
um
b
er
is
displa
y
ed
in
large
c
haracters, and
the measuremen
t results
are
displa
y
ed
in normal
characters.
BIN
COUNT
DISPLA
Y
(under
4
DISPLA
Y
F
ORMA
T
5
)
This
displa
y
page
pro
vides
the
limit
table's
conditions,
and
the
comparator's
bin
coun
ter
results.
The
4284A
can
measure
the
device
under
test
from this
page, but
the
measuremen
t
results
will
not
b
e
displa
y
ed.
LIST SWEEP
DISPLA
Y
(under
4
DISPLA
Y
F
ORMA
T
5
)
This
displa
y
page
pro
vides
the
list
sw
eep
measuremen
t
results,
and
the
sw
eep
mo
de
step/seq
selection.
The 4284A
measures
the
device
under
test
according
to
the
list
sw
eep
conditions
in
the
LIST
SWEEP
SETUP
page.
An
asterisk
(
*
)
sho
ws
the
curren
t
measuring
p
oin
t
in
the
list
sw
eep p
oints.
The
list
sw
eep
p
oin
t
cannot
b
e
set
from
this
page.
Y
ou
m
ust
use
the
LIST
SWEEP SETUP
(in
4
MEAS
SETUP
5
)
page
to
set
the
list
sw
eep
p
oin
ts.
MEAS
SETUP
(under
4
MEAS
SETUP
5
)
This
displa
y page
provides
all of
the measuremen
tcon
trol settings.
The
4284A
cannot
p
erform
a
measuremen
t
from this
page,
and
the
measurement result can not be displa
yed
on this page. When y
ou
measure the device under test using the con
trol settings on this page,
use one of the displa
y pages from
4
DISPLAYF
ORMAT
5
.
CORRECTION (under
4
MEAS SETUP
5
)
This displa
y page pro
vides the correction function. The correction
function m
ust b e used to
measure the device under test accurately
.
The 4284A cannot measure the device under test from this page, and
the measurement results will not b e displayed. When you measure a
device under test, use one of the display pages from
4
DISPLAYFORMAT
5
.
2-10 Overview

Other manuals for Agilent Technologies 4284A