Do you have a question about the Agilent Technologies 4349B and is the answer not in the manual?
Model | 4349B |
---|---|
Manufacturer | Agilent Technologies |
Category | Measuring Instruments |
Type | High Resistance Meter |
Frequency | DC |
Display | LCD |
Interface | GPIB, RS-232 |
Measurement Parameters | Resistance, Voltage, Current |
Power Supply | 100/120/220/240 VAC, 50/60 Hz |
Weight | Approx. 10 kg |
Provides an overview and basic procedures for using the 4349B.
Guides the user through the front panel layout and key functions.
Explains the components and connections on the rear panel of the instrument.
Specifies power requirements, including voltage, frequency, and fuse.
Explains how to operate the 4349B using its front panel keys.
Directs users to troubleshooting information for issues encountered.
Introduces the chapter on operating the 4349B, covering installation and configuration.
Shows the typical measurement system setup using the 4349B.
Guides users on configuring measurements, including resetting and OPEN correction.
Describes how to select the measurement range, including Auto and Hold modes.
Details how to enable or disable the contact check function.
Explains the methods for making measurements after configuring the instrument.
Introduces the chapter on functions and their reference.
Details the display and annunciator functions on the front panel.
Details the input terminals for connecting DUTs.
Explains how to select different display modes.
Details how the key toggles the comparator function.
Explains how the key toggles the contact check function.
Explains the various connectors and controls on the rear panel.
Explains the GPIB interface for remote control of the 4349B.
Explains the basic theory of operation for the 4349B.
Introduces operating the 4349B via GPIB remote mode.
Explains how to send commands to the 4349B remotely.
Details commands to trigger measurements from an external controller.
Provides troubleshooting steps for common GPIB problems.
Introduces GPIB commands for controlling the 4349B.
Details common commands used for managing macros, data storage, etc.
Explains subsystem commands for signal generation and control.
Explains the syntax for constructing SCPI program messages.
Details commands for the CALCulate subsystem.
Details commands related to measurement parameters and conditions.
Introduces actual measurement examples and notes on insulation resistance.
Shows a high throughput measurement example for capacitors.
Guides on selecting the optimum measurement range for accuracy.
Provides general information about the 4349B.
Lists the instrument's measurement parameters and conditions.
Details the resistance and current measurement ranges.
Introduces the chapter on maintaining the 4349B.
Outlines procedures for verifying instrument specifications.
Details procedures for testing current measurement accuracy.
Guides on testing resistance measurement accuracy.
Lists and explains instrument error messages.
Lists and explains GPIB-related error messages.