EasyManua.ls Logo

Agilent Technologies 81101A - Page 71

Agilent Technologies 81101A
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
71
Programming Reference
SCPI Instrument Command List
Command :VOLT[1]:OFFSet
Long
[:SOURce]:VOLTage[1][:LEVel][:IMMediate]:OFFSet
Form Set & Query
Parameter Numeric
Parameter suffix
V
with engineering prefixes.
Value coupling
Range coupling With Amplitude, see page 70
*RST value 0.0 mV
Specified Limits –10 V to +10 V
Description Use this command to program the offset voltage of the OUTPUT signal.
Note that to set the OUTPUT levels in terms of voltage, you first have to
execute the
[:SOURce]:HOLD VOLTage
command to enable the
[:SOURce]:VOLtage
subsystem.
The available voltage range is limited by the combination of:
Specified current limits
Actual OUTPUT impedance setting
:OUTPut:IMPedance
Actual expected load impedance setting
:OUTput:IMPedance:EXTernal
Example To set the offset voltage:
High = Offset +
Amplitude
2
Low = Offset –
Amplitude
2
:HOLD VOLT
:VOLT:OFF –800MV
Enable VOLTAGE subsystem
Set OUTPUT offset to –800mV

Other manuals for Agilent Technologies 81101A

Related product manuals