Language Reference
ACPBRWID Adjacent Channel Power Burst Width
ACPBRWID Adjacent Channel Power Burst
Width
Syntax
Figure 7-12 ACPBRWID Syntax
Description
The ACPBRWID command sets the on-time (pulse width) of the burst
RF signal. The pulse width is needed to set the gating times when using
the gated method for adjacent channel power measurements.
Parameters
number 5 µs to 9.5 seconds
Query Response
Figure 7-13 ACPBRWID Query Response
Example
10 REAL Burstwidth
20 Burstwidth = 6.53
30 OUTPUT 718;"ACPBRWID";Burstwidth;"MS;";