EasyManuals Logo

Agilent Technologies E3614A User Manual

Agilent Technologies E3614A
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
1-10-2
Programming Voltage Common to the Minus Output
Figure 2
Set the CV switch down on the rear panel, and all others up.
V
in
= 1/A x V
out
V
out
= A x V
in
Where V
out
is the power supply output voltage.
V
in
is the programming voltage.
A is the gain factor and the values of each model are as below.
Alternative Voltage Programming Using Resistors
Programming Voltage Common to the Plus Output
Figure 3
The M/S2 switch must be in the down position. For best results, place a 0.1µF capacitor in
parallel with R2.
V
in
= (R1/R2) x V
out
V
out
= (R2/R1) x V
in
Where V
out
is the power supply output voltage.
V
in
is the programming voltage.
R1 and R2 should be in the 1K to 100K range.
Model A 1/A
E3614A 0.44 2.25
E3515A 0.67 1.5
E3616A 0.78 1.29
E3617A 0.86 1.17