1.
The
4
MSG
5
ke
y
allows
you
to
displa
y
an
y
error
messages
on
the
front
panel
displa
y
.
Error
messages are
generated when
you
perform
a
ke
ystroke
sequence
that
is
not
valid,
try
to
operate
the
synthesizer
in
a
mode
that is
not
allowed,
etc
.
2.
The
4
SHIFT
5
ke
y
changes
the
function
of
some
of
the
ke
ys.
When
you
press
the
4
SHIFT
5
key
and
then
press
another
ke
y
,
the
synthesizer
performs
the
function printed
in
blue
above
the
ke
y
.
3.
The
4
RECALL
5
/
SA
VE
ke
y
is
used
to
save
most
of
the
synthesizer
operating
parameters
in
one
of
nine
nonvolatile
register
locations
so
that the
ycan
be recalled
and
used
at a
later
time
.
4.
The
Automatic
L
evel
Control
ke
ys select
the method
used to
regulate
the
synthesizer
output
power
level.
Either
internal
leveling,
external
power
meter
leveling,
or
external
diode
detector
leveling
can
be
selected.
Additional
external
equipment
is
required
when
either
external power
meter
leveling
or
external
diode
detector
leveling
is
used.
5.
These
ke
ys
set
the
carrier
frequenc
y and
RF
output
power
level
of
the
synthesizer
.
6.
The displa
y shows
the
current
values
of
synthesizer
parameters
as
well
as
the
status
of
man
y
of
the
synthesizer
functions.
The
displa
y shows
the current
carrier
frequenc
y
and
output
power
level.
The
annunciators
that
appear
below
the
parameters
are
only
visible
when their
associated
function
is
active
.
7.
The
4
(
5
and
4
)
5
ke
ys
move
the cursor
that
is
over
one
of
the
digits
in
the
display
either
to
the
right
or
left
when
pressed.
The
digit
that
is
under
the
cursor
will
be
modied
when
the
knob
is
rotated.
If
no
cursor
appears
in
the displa
y,
parameter entry
or
modication
has been
inhibited.
8.
The
RF
OUTPUT
connector
mates
with
a
Type-N
male connector
on
non-Option
1E9
instruments.
The
connector
mates
with
a
female
APC-3.5
mm
precision
connector
on
instruments
with
Option
1E9
installed.
9.
The
knob
is
used
to
increase
or
decrease
the
digit
under
the cursor
(
9
)
in
the
displa
y
in
steps
of
one
.
10.
The
data
entry
ke
ys
are
used
to enter
and
modify
various
synthesizer
parameters.
The
4
B
A
CKSP
ACE
5
key
cancels all
or
part
of
an
erroneous
parameter
entry
before
it
has
been
terminated.
The
terminator
ke
ys
(the
right-most column
of
ke
ys)
are
used
to
choose
the
units
for
the
entered
parameter
as
well
as
to
terminate
the
parameter
entry
.
The
4
*
5
,
4
+
5
, and
4
STEP
SIZE
5
keys
are
used
to
increase
or decrease
a parameter
in
predetermined
steps.
11.
The
Automatic
L
evel
Control
voltage
input
(AL
C
IN)
connector
is
used
as
the
feedback
path
to
the
synthesizer
when
its
RF
output
power
level
is being
leveled externally
.
12.
The
4
SPCL
5
key
is
used
to
initiate
the
activation
of
several
special
functions
available
in the
synthesizer.
Special
functions
are
additional
functions
that
are
not
activated
b
y
pressing
a
front
panel ke
yor
shifted ke
y
.
13.
The
POWER
switch
(LINE
on
an
HP
83711A/12A)
turns
the
synthesizer
either
on
or
o.
Synthesizer
rear
panel
features
are
depicted
and
described
in
detail
in
Chapter
5,
\Front/Rear
P
anel,"
in
this
book.
v

Other manuals for Agilent Technologies HP 83711B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies HP 83711B and is the answer not in the manual?

Agilent Technologies HP 83711B Specifications

General IconGeneral
BrandAgilent Technologies
ModelHP 83711B
CategoryTest Equipment
LanguageEnglish

Related product manuals