EasyManuals Logo
Home>Agilent Technologies>Portable Generator>N5183A

Agilent Technologies N5183A User Manual

Agilent Technologies N5183A
366 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
88 Agilent N518xA, E8663B, E44x8C, and E82x7D Signal Generators Programming Guide
Programming Examples
GPIB Programming Interface Examples
}
Saving and Recalling States Using VISA and C
In this example, instrument settings are saved in the signal generator’s save register. These settings
can then be recalled separately; either from the keyboard or from the signal generator’s front panel.
Launch Microsoft Visual C++ 6.0, add the required files, and enter the following code into your .cpp
source file. visaex8.cpp performs the following functions:
•error checking
• clears the signal generator
• resets the status byte register
• resets the signal generator
• sets up the signal generator frequency, ALC off, power level, RF output on
• checks for operation complete
• saves to settings to instrument register number one
• recalls information from register number one
• prompts user input to put instrument into Local and checks for operation complete
The following program example is available on the signal generator Documentation CD- ROM as
visaex8.cpp.
//****************************************************************************************
// PROGRAM FILE NAME:visaex8.cpp
//
// PROGRAM DESCRIPTION:In this example, instrument settings are saved in the signal
// generator's registers and then recalled.
// Instrument settings can be recalled from the keyboard or, when the signal generator
// is put into Local control, from the front panel.
// This program will initialize the signal generator for an instrument state, store the
// state to register #1. An *RST command will reset the signal generator and a *RCL
// command will return it to the stored state. Following this remote operation the user
// will be instructed to place the signal generator in Local mode.
//
//****************************************************************************************
#include <visa.h>
#include "StdAfx.h"
#include <iostream>
#include <conio.h>
void main ()
{
ViSession defaultRM, vi;// Declares variables of type ViSession
// for instrument communication
ViStatus viStatus = 0;// Declares a variable of type ViStatus

Table of Contents

Other manuals for Agilent Technologies N5183A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies N5183A and is the answer not in the manual?

Agilent Technologies N5183A Specifications

General IconGeneral
BrandAgilent Technologies
ModelN5183A
CategoryPortable Generator
LanguageEnglish

Related product manuals