Ei3028 / 3018
Alarms
Instruction Manual
Read and retain carefully for as long as the product is being used. It contains vital
information on the operation and installation of your Alarm. The leaflet should be
regarded as part of the product.
If you are just installing the unit, the leaflet MUST be given to the householder. The
leaflet is to be given to any subsequent user.
Mains Powered

Questions and Answers

  • R
    robertpaceJul 27, 2025
    Why does my Aico Ei3018 alarm go off for no reason?
    • A
      Adam PaulJul 27, 2025
      If your Aico Security System alarm sounds for no obvious reason, first locate the alarm with the flashing red LED to identify whether it's a Fire or CO (Ei3028) alarm. For fire alarms, if it's a nuisance alarm, press the Test/Hush button to silence it and interconnected devices for 10 minutes; press again for more silenced time. Relocate the alarm if false alarms are frequent. If the alarm continues to sound without smoke or heat, and cleaning doesn't help, replace it. For CO alarms, check for fuel-burning appliances, fumes, aerosols, outdoor CO sources, hydrogen sources (like charging batteries), or excessive smoke from hookahs. Press the Test/Hush button to silence the alarm for 4 minutes. If it persists, the CO alarm may be defective and should be replaced.
  • D
    donaldthomasAug 2, 2025
    What to do if interconnected Aico Ei3018 Security System alarms do not all sound?
    • S
      Samuel YoungAug 2, 2025
      If interconnected Aico Security System alarms don't all sound, hold the test button for 10 seconds after the first alarm sounds to ensure the signal transmits to all units. For hardwired interconnections, consult a qualified electrician. If using a RadioLINK system with an RF module, verify that all alarms are powered and house-coded correctly.
  • K
    Kevin MacdonaldAug 9, 2025
    How to troubleshoot Aico Security System alarm not sounding when testing?
    • D
      Dustin NicholsAug 9, 2025
      If your Aico Security System alarm doesn't sound when you press the test button, ensure the alarm is correctly secured on the mounting plate. Wait 15 seconds after connecting the power before testing. Hold the button down firmly for at least 10 seconds. If the horn still doesn't sound, the alarm must be returned for repair or replacement.
  • G
    gregorysimmonsAug 15, 2025
    What to do if the Test/Hush button doesn't silence my Aico Security System alarm?
    • J
      Jesse ChangAug 15, 2025
      If pressing the Test/Hush button doesn't silence the Aico Security System alarm, ensure you are pressing the Test/Hush button on the alarm that is sounding with the red LED flashing.
  • J
    Jessica ArmstrongAug 21, 2025
    How to fix low battery backup fault on Aico Ei3018?
    • N
      nicholas22Aug 21, 2025
      If there is a low battery backup fault in your Aico Security System, first check that the green LED power indicator is continuously on. Next, check fuses, circuit breakers, and wiring to find the cause of the interruption to the mains power. If problems persist, the alarm must be returned for repair or replacement.

Summary

Introduction to Ei3028;3018 Alarms

Alarm Overview

Provides a general overview of the Ei3028 and Ei3018 alarms.

Technical Specifications

Details the technical specifications and features of the alarms.

Alarm Installation Guide

Important Safety Instructions

Crucial safety guidelines for installing mains-powered alarms.

Where to Locate the Alarm

Guidance on selecting optimal locations for alarm installation.

Which Alarm for Which Room

Table indicating the suitability of Ei3028 vs Ei3018 for different rooms.

Placement Within the Room

Specific placement advice for ceiling and wall mounting within rooms.

Unsuitable Locations for Installation

Lists areas where alarms should not be installed to ensure proper function.

Mounting and Wiring Procedures

Step-by-step instructions for physically mounting and wiring the alarms.

Interconnecting Alarms

Explains how to link multiple alarms for integrated warning systems.

Removing the Alarm Unit

Instructions on how to safely disconnect the alarm from its mounting base.

Understanding Carbon Monoxide

Symptoms of CO Poisoning

Details the symptoms associated with carbon monoxide poisoning.

Protecting Your Family from CO

Provides essential guidelines to prevent carbon monoxide exposure.

How the Alarm Detects CO

Explains the operational principles and indicators of the alarm system.

Alarm Testing and Maintenance

Testing and Maintaining Your Alarm

Guidelines for regular testing and maintenance to ensure alarm functionality.

Cleaning Your Alarm

Instructions on how to clean the alarm unit to maintain performance.

Emergency Procedures

What to Do in Case of Fire

Outlines immediate actions to take in the event of a fire.

What to Do if Your Alarm Detects Carbon Monoxide

Steps to follow when the alarm detects carbon monoxide.

Troubleshooting and Indicators

Important Safeguards and Limitations

Limitations of Heat and CO Alarms

Discusses the limitations of heat and CO alarms and their proper use.

Service and Guarantee Information

Getting Your Alarm Serviced

Information on how to obtain service for the alarm unit.

Product Guarantee Details

Details the warranty period and terms for the alarm product.

Aico Ei3018 Specifications

General IconGeneral
Sensor TypeOptical
Test ButtonYes
Battery LifeUp to 10 years
Power SourceMains Powered with Lithium Battery Backup
InterconnectivityYes
Alarm Volume85 dB
LED IndicatorYes
Standards ComplianceEN 14604:2005
Operating Temperature0°C to 40°C