EasyManua.ls Logo

Aico Ei3018 - Which Alarm for Which Room

Aico Ei3018
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
However, if the number of CO Alarms is limited, the following points should be considered when
deciding where best to fit the alarm(s).
- If there is an appliance in a room where people sleep, place a CO Alarm in this room
- Locate a CO Alarm in a room containing a flueless or open-flued appliance
- Locate a CO Alarm in a room where the occupant(s) spend most of their time (e.g. living room)
- In a bedsit, the CO Alarm should be placed as far away from the cooking appliance as possible, but
near to where the occupant sleeps
- If the appliance is in a room not normally used (such as a boiler room) the CO Alarm should be
placed just outside the room so that the alarm will be heard more easily.
2.3 Which Alarm In what room?
Location
Ei3028
Heat and CO
Alarm
Ei3018
CO
Alarm
Kitchens with Fuel Burning appliance
Garages with Fuel Burning appliance
Boiler houses
Areas with high levels of fumes, smoke or dust and
risk of CO
Any other rooms with Fuel Burning appliance
Any other rooms with risk of CO poisoning

Related product manuals