4=2
4-1
Standard
System
(1)
[1]
Entrance
Station
[2]
Door
release
timer
(set
Set
the
duration
for
the
d<
release
button
is
pressed.
[0.5]
-
[20]:
0.5
secs
-
20
secs
[20]
-
[M]:
Activates
while
the
button
is
pressed.
[3]
Setting
switch
(GH-DA/A)
SW2:
1:
Setting
switch
for
camera
entrance
station
monitoring
function
(set
to
OFF
at
time
of
shipment)
ON
(Up):
Monitored.
OFF
(Down):
Skipped
at
time
of
entrance
station
monitoring.
SW2:
2-4
....
A
When
installing
multiple
entrance
stations,
make
sure
to
set
the
GH-DA/A
ID
numbers
(SW2).
[4]
External
signaling
relay
GH-RY
For
details,
see
4-5.
[5]
Door
release
relay
contact
Less
than
AC/DC
24
V,
4
A
(resistance
load)
PT:
AC
Transformer
For
connecting
the
access
control
keypad
module
GF-AC,
refer
to
the
GF-AC
Installation
&
Operation
Manual.
[6]
Security
guard
station
GH-MK
[7]
Setting
switch
(GH-MK)
SW1:
1:
Password
reset
switch
Set
the
password
reset
switch
to
ON
for
2
seconds
or
more
during
standby
will
reset
the
password
(set
to
"*
1111"
at
time
of
shipment).
SW1:
2,
3:
Unused
switch
SW1:
4:
Security
guard
station
number
setting
switch
(set
to
#1
at
time
of
shipment)
A
When
installing
two
security
guard
stations,
make
sure
to
set
the
ID
numbers
(SW1).
[8]
Doorbell
button
[9]
Power
supply
PS-2420UL
[10]
Video
Bus
control
unit
GH-VBC
(SW2:
STD)
[11]
Video
Bus
control
unit
GH-VBC
(SW2:
EXP)
To
use
GH-VBC
as
an
extension
adaptor,
set
the
setting
switch
to
"EXP".
Connect
only
"INI"
terminal
at
input
side.
[12]
Bus
control
unit
GH-BC
[13]
Distribution
terminal
(junction):
Not
included
NP:
Non-polarized
4-2
Standard
System
(2)
Station-to-Station
Wiring
[1]
Residential
station
GH-1KD,
GH-1AD
There
can
be
a
maximum
of
25
stations
per
trunk.
For
the
terminating
residential
station
GH-1KD,
set
the
setting
switch
(SW1)
to
"A".
[2]
Short
lead
To
use
the
emergency
alarm
switch
(see
11-7
for
details),
disconnect
the
short
lead
and
connect
the
switch.
[3]
Option
Connector
For
details,
see
4-6.
A
The
separate
option
connecter
is
required.
[4]
Doorbell
button
A1.
Do
not
mix
station-to-station
wiring
with
homerun
wiring.
A
2.
Station-to-station
wiring
is
not
possible
for
GH-1MD.