- 9 -
Wiring Connection
■ Multi-purpose adaptor IXW-MA connection example
*1 Contact Input Specifications
*2 Relay Output 1 to 4 Specifications
• Insulate and secure unused low-voltage lines and the connector-attached lead wire.
Input method Programmable dry contact (N/O) or (N/C)
Level detection method
Detection time 100 msec or more
Contact resistance Make: 700 Ω or less
Break: 3 kΩ or more
Terminal short-circuit current 10 mA or less
Voltage between terminals 5 VDC or less (between open terminals)
Output method Form C dry contact closure (N/O or N/C)
Contact rating 24 VAC, 0.5 A (resistive load)
24 VDC, 0.5 A (resistive load)
Minimum overload (AC/DC): 100 mV, 0.1 mA
NO3 COM3
NC3
NO4 COM4
NC4
NO1 COM1
NC1
NO2 COM2
NC2
S1 SE1 S2 SE2 S3 SE3 S4 SE4
2LE 2CL 3LR 3LE 3CL1LR 1LE 1CL
1T1 1T2
2T1 2T2 3T1 3T2
2LR
NO8 COM8
NO9 COM9 NO10 COM10
NO5 COM5 NO6 COM6NO7 COM7
IXW-MA
Not used
Contact input 1 to 4
Relay output 1 to 2 Relay output 3 to 4 Relay output 5 to 7 Relay output 8 to 10
Same as Relay output 1 to 2.
Same as Relay output 5 to 7.
Relay output 
5 to 7 *
3
Relay output 
1 to 
2 *
2
Contact input 
1 to 4 *
1
PE0.65mm(22AWG)-2C
PE0.65mm(22AWG)-2C
PE0.65mm(22AWG)-2C
PoE switch
100m (330')
LAN/PoE
(IEEE802.3af)
Cat-5e/6 straight
Multi-purpose Adaptor
Red
Brown
Orange
Yellow
Green
Blue
Gray
Purple
Red
Brown
Orange
Yellow
Green
Blue
Red
Brown
Orange
Yellow
Green
Blue
Red
Brown
Orange
Yellow
Green
Blue
Red
Brown
Orange
Yellow
Green
Blue
Not usedNot used
Not used Not used Not used