CONSOLE
EVAPORATIVE
HUMIDIFIER
H12SERIES
USEANDCAREGUIDE
AdjustableHumidistat
FourSpeedFan
EasyFillWaterBottle

TOORDERPARTSANDACCESSORIESCALL 1.800.547.3888
1B72893 11/2014 Printed in China
READ AND SAVE THESE INSTRUCTIONS
COMFORT IS IN THE AIR
®
Français ………….13
Español ………..…25
H12 300HB;
H12 400HB

Questions and Answers

  • L
    Linda MurrayAug 16, 2025
    What does it mean when my Aircare H12 displays alternating “F” and room humidity?
    • A
      Amy MartinAug 16, 2025
      If your Aircare Humidifier is displaying alternating “F” and room humidity, it means the reservoir is empty, and the float isn't activating the switch on the chassis. Fill the humidifier with water and reposition the chassis so that the float and switch are aligned.
  • M
    mitchell55Aug 18, 2025
    What to do if my Aircare Humidifier is not producing enough humidity?
    • J
      Jeffrey MorrisonAug 18, 2025
      If your Aircare Humidifier isn't producing enough humidity, it might be due to an old or clogged wick. Try replacing the wick, especially if it feels hardened with minerals. Also, check the humidistat setting on the control panel and increase it.
  • J
    Jason ReidAug 21, 2025
    Why is my Aircare Humidifier leaking water?
    • J
      Joseph KirbyAug 21, 2025
      A water leak in your Aircare Humidifier could be because the water reservoir was overfilled. Avoid overfilling the bottle and reservoir. Also, ensure that you haven't punctured the bottle in an attempt to make it drain faster, as this can also cause leaks. Do not puncture the bottle.
  • O
    ohooverAug 25, 2025
    What to do if my Aircare Humidifier unit does not operate on any speed setting?
    • D
      Daniel CochranAug 25, 2025
      If your Aircare Humidifier isn't working on any speed, first, make sure the polarized plug is fully inserted into the wall outlet to ensure it has power. Also, the fan will not operate without water, so refill the water bottle. Finally, check that the float assembly is correctly positioned.
  • C
    Christopher BowenAug 28, 2025
    Why does my Aircare Humidifier have too much humidity, causing condensation?
    • E
      eric91Aug 28, 2025
      If you're experiencing too much humidity with your Aircare Humidifier, resulting in heavy condensation, it's likely that the humidistat is set too high. Try reducing the humidistat setting or increasing the room temperature.
  • S
    Sharon ScottAug 30, 2025
    How to fix Aircare H12 water not draining into the reservoir?
    • P
      petersonjoshuaAug 30, 2025
      If water isn't draining into the reservoir of your Aircare Humidifier, unplug the unit. Remove the water bottle and reassemble without it. Turn the unit on to see if the fan comes on. If it does, replace the water bottle and continue operation. If the unit has overheated, take unit to authorized service station and do not attempt electrical repairs yourself.
  • D
    Debra BrownSep 2, 2025
    What does it mean when my Aircare H12 displays alternating “CF” and room humidity?
    • D
      darlenegarciaSep 3, 2025
      If your Aircare Humidifier displays alternating “CF” and room humidity, the wick may be dirty. Replace the wick if needed. Unplug the unit for 30 seconds and plug it back in to clear the display.
  • T
    Tracy GonzalezSep 6, 2025
    Why does my Aircare H12 have an odor?
    • M
      Mr. Andrew Walker DDSSep 6, 2025
      If your Aircare Humidifier has an odor, it may be due to the presence of bacteria. Clean and disinfect the cabinet following the care and maintenance instructions. You can also add an EPA-registered bacteria treatment according to the instructions on the bottle. If the odor persists, it might be necessary to replace the wick.
  • K
    kmarshSep 8, 2025
    What to do if the “CF” message does not appear on my Aircare Humidifier?
    • M
      Michael RiveraSep 9, 2025
      If the “CF” message does not appear on your Aircare Humidifier even when the wick is dirty or humidifier performance is clearly reduced, it indicates that a loss of power or a power failure has caused the CF message to prematurely reset. Replace the wick.
  • A
    Andrea WilsonSep 12, 2025
    How do I test the motor on my Aircare H12 Humidifier?
    • K
      karidavisSep 12, 2025
      To test the motor on your Aircare Humidifier, turn the unit ON and turn all dials fully ON. Turn the chassis over and insert finger into tab where float rod is supposed to go. If fan turns on, the fan and motor are working correctly. Use caution and do not touch the fan when accomplishing this test, as the motor may turn on.

Summary

IMPORTANT SAFEGUARDS

ASSEMBLY

Evaporative Wick Installation

Steps for correctly placing the evaporative wick and float assembly into the unit.

Filling Information

Details on filling the water bottle and reservoir, including cautions and recommendations.

CONTROLS AND OPERATION

Fan Speed Adjustment

How to adjust the fan speed using the control knob and what the display shows.

Humidity Control Operation

How to set and use the adjustable humidistat for desired humidity levels.

CARE AND MAINTENANCE

TROUBLESHOOTING

LIST OF REPLACEMENT PARTS

HUMIDIFIER TWO YEAR LIMITED WARRANTY POLICY

Aircare H12 SERIES Specifications

General IconGeneral
HumidistatYes
Fan Speeds3
Power Source120V AC
Warranty1 year limited