800.909.9709
www.AirCycle.com [11]
Operating Procedures for Linear
Lamps
WARNING – DO NOT TAMPER WITH ANY ELECTRICAL CONTROL DEVICES ON THIS MACHINE
Before Operating the Bulb Eater
®
3
• Communicate/understand potential hazards by having operators review pages 24-29 of this manual
and complete online training program at www.BulbEater3Training.com
Note: The Bulb Eater
®
3 machine is inoperable until key personnel have completed this online training
program. Details to activate the Bulb Eater
®
3 machine will be provided immediately upon completion
of the program
• Before crushing, label drum as containing Mercury (D009) and as either Hazardous Waste or
Universal Waste depending on your state requirements
• Crush lamps in a well-ventilated area
• Wear safety glasses, protective gloves, and ear protection
• Screw in entry tube for crushing linear lamps
• Remove rubber plug from top of entry tube
• Crush only linear fluorescent lamps
1. Plug the machine in & release the E-STOP button. The machine will go through 3 LCD display
functions – Stopping, Dumping, Ready.
2. Take the plug out of the entry tube.
3. Press the START button. When the LCD screen displays ready.
4. Insert the linear lamp into the entry tube and then let go. Do not force the lamp down the entry tube.
5. The machine will time out when the cyclone counter zeros out, followed by 3 LCD display functions –
Stopping, Dumping, Ready.
6. To continue crushing press the START button.
7. After crushing, press the STOP button to stop the crusher motor. The machine will go through 3 LCD
display functions again – Stopping, Dumping, Ready.
8. When the LCD display indicates “Ready”, press the E-STOP button and seal the entry tube. Figure 1
When the machine is not in use, make sure that all openings are sealed (sealed entry tube and CFL
chute may remain on the machine when not in operation).
9. Before removing lid: Let the machine sit OFF for at least 15 minutes after the dump cycle is done to
allow dust to settle before opening the lid during drum change.
Notes: 1. Pressing the STOP button must be completed before pressing the E-STOP button when
finished crushing, this will allow the powder to be dumped out of the cyclone into the drum.
2. When crushing linear lamps, insure that the CFL/U-Tube chute is removed and the safety cover
is installed.
ATTENTION:
Drum MUST be kept closed at all times