EasyManua.ls Logo

Airo SF series - On-Off Key and Control Station Selector (A); Emergency STOP Button (B); Diesel;Electric Power Selector (C); Heat Engine Starting Switch (D)

Airo SF series
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Use and maintenance manual Self-propelled aerial platforms Page 27
L) Oil warning light (models “Dand “E/D”);
M Air filter warning light (models D” and “E/D”);
N) Motor head temperature warning light (models “Dand “E/D);
O) Lifting/lowering lever;
P) Front roll-out deck extraction/retraction lever (OPTIONAL);
Q) Rear roll-out deck extraction/retraction lever (OPTIONAL);
R) Sliding platform extraction/retraction lever (OPTIONAL).
The key must be given to authorized personnel. Keep a duplicate key in a safe place.
Always remove the on/off key at the end of work shifts.
5.2.1.1 On-off key and control station selector (A)
The on-off key located on the ground control station is used to:
- turn ON the machine by selecting one of the two control stations:
- platform controls enabled with key switch set to “platform” symbol. Stable key position with possibility to extract the
key;
- ground controls enabled (for emergency operations) with key switch set to “chassis” symbol. Position with action to
be kept. When the key is released the machine is turned off.
- turn OFF the control circuits by turning it to OFF;
- turn ON the battery charger by turning it to OFF (models “E” and “E/D”).
5.2.1.2 Emergency STOP button (B)
By pressing this button the machine (as well as the heat engine on models D”, “E/D and “E/B”) is completely stopped; by
rotating it of 1/4 turn (clockwise) the machine can be turned ON by means of the ON-OFF key (see chapter 5.2.1.1).
5.2.1.3 Diesel/electric power selector (C)
Holding the ON-OFF key in position “ground controls” it is possible to select the type of power for the ground controls:
- If ELECTRIC is selected and the ON-OFF key is kept active in position “ground controls” the electric pump is started
while operating the ground controls;
- If DIESEL is selected and the ON-OFF key is kept active in position “ground controls” the Diesel engine can be started.
5.2.1.4 Heat engine starting switch (D)
Holding the ON-OFF key in position “ground controls after selecting the DIESEL power, the diesel engine can be started by
means of the relevant switch.
- In “0” position the Diesel engine is off;
- In “3 sec” position the plugs pre-heating takes place (only for engines with plugs);
- In “Start” position the engine starts.

Table of Contents

Related product manuals